Flow-through multianalyte chemiluminescent immunosensing system with designed substrate zone-resolved technique for sequential detection of tumor markers.

نویسندگان

  • Zhifeng Fu
  • Hong Liu
  • Huangxian Ju
چکیده

A novel flow-through immunosensing system for performing a multianalyte chemiluminescent determination in a single run was designed. A new analytical strategy of substrate zone-resolved technique was proposed. Using carcinoma antigen 125 (CA 125) and carcinoembryonic antigen (CEA) as model analytes, the capture antibodies for CA 125 and CEA were immobilized on an UltraBind aldehyde-activated membrane to act as an immunoreactor, to which the mixture of CA 125, CEA, and their corresponding tracers, horseradish peroxidase (HRP)-labeled anti-CA 125 and alkaline phosphatase (ALP)-labeled anti-CEA, was introduced for on-line incubation. The substrates for HRP and ALP were then delivered into the detection cell sequentially to perform substrate zone-resolved immunoassay by a sandwich format. Under optimal conditions, CA 125 and CEA could be assayed in the ranges of 5.0-100 units/mL and 1.0-120 ng/mL, respectively. The whole assay process including incubation, wash, detection, and regeneration could be completed in 35 min. The serum samples from the clinic were assayed with the proposed method, and the results were in acceptable agreement with the reference values. This method and the strategy of substrate zone-resolved technique could be further developed for high-throughput multianalyte immunoassay.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A channel-resolved approach coupled with magnet-captured technique for multianalyte chemiluminescent immunoassay.

A concept of channel-resolved multianalyte immunoassay (MAIA) and a semi-automated flow-through chemiluminescent (CL) MAIA system coupled with magnet-captured technique were proposed for rapid quantitation of different analytes in a single run. Using alpha-fetoprotein (AFP), carcinoembryonic antigen (CEA) and carcinoma antigen 125 (CA 125) as model analytes. They were firstly incubated in the m...

متن کامل

Multiplex tumor marker detection with new chemiluminescent immunoassay based on silica colloidal crystal beads.

A new multiplex chemiluminescent immunoassay (CLIA) based on silica colloidal crystal beads (SCCBs) was developed for tumor marker detection. As the code is the characteristic reflection peak originating from the stop-band of colloid crystal, they avoid photobleaching, the potential interference of encoding fluorescence with analyte-detection fluorescence and chemical instability. Meanwhile our...

متن کامل

Channel and substrate zone two-dimensional resolution for chemiluminescent multiplex immunoassay.

A two-dimensional resolution system of channels and substrate zones was proposed for multiplex immunoassay performed with a designed multichannel chemiluminescent (CL) detection device coupled with a single photomultiplier. Using carcinoma antigen 125 (CA 125), carcinoma antigen 153 (CA 153), carcinoma antigen 199 (CA 199), and carcinoembryonic antigen (CEA) as two couples of model analytes, tw...

متن کامل

Inkjet-printed paperfluidic immuno-chemical sensing device.

This paper reports on an inkjet printing method for the fabrication of lateral flow immunochromatographic devices made from a single piece of filter paper by patterning microfluidic channels and dispensing immunosensing inks, requiring only a single printing apparatus. This "paperfluidic" immunosensing device allows for a less time-consuming and more low-cost fabrication compared with the conve...

متن کامل

A disposable multianalyte electrochemical immunosensor array for automated simultaneous determination of tumor markers.

BACKGROUND Automated and convenient multianalyte detection with high throughput is increasingly needed in clinical diagnosis. We developed a disposable 4-by-2 array for programmed simultaneous amperometric immunoassay of 4 tumor markers. METHODS We used a screen-printed technique, 1-step immobilization method, and flow injection technique. We immobilized carcinoembryonic antigen, alpha-fetopr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 78 19  شماره 

صفحات  -

تاریخ انتشار 2006