The limits of passive motion are variable between and unrelated within normal tibiofemoral joints.

نویسندگان

  • Joshua D Roth
  • Maury L Hull
  • Stephen M Howell
چکیده

Patient-to-patient differences should be accounted for in both clinical evaluations and computational models of knee laxity. Accordingly, the objectives were to determine how variable the laxities are between knees by determining the range of the internal-external (I-E), varus-valgus (V-V), anterior-posterior (A-P), and compression-distraction (C-D) limits of passive motion, and how related the laxities are within a knee by determining whether these limits are correlated with one another. The limits in I-E (± 3 Nm), V-V (± 5 Nm), A-P (± 45 N), and C-D (± 100 N) were measured in 10 normal human cadaveric knees at 0° to 120° flexion in 15° increments using a six degree-of-freedom load application system. The ranges from 15° to 120° flexion of the I-E limits were greater than 3.6°, of the A-P limits were greater than 1.8 mm, and of the varus limits were greater than 1.4°. The ranges from 30° to 120° flexion of the distraction limits were greater than 2.0 mm. Twenty-four of the 28 pair-wise comparisons between the limits had a correlation coefficient less than 0.65. These results demonstrate that a patient-specific approach, including all degrees of freedom of interest, is necessary during clinical evaluations of laxity and when creating and validating computational models of the tibiofemoral joint.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Kinetic and Kinematic Variables in Middle-Aged Women with Normal and Genu Varum Knee Angle with Emphasis on Walking and Running Activities

Purpose: The purpose of this study is to examine the differences of kinetic and kinematic variables in middle-aged women with genu varum and normal knee angle during walking and running. Methods: Eight middle-aged women with genu varum (age: 45.12 ±12.74 y, height: 160.62 ± 5.26 cm, weight: 71.75 ± 16.38 kg, right tibiofemoral angle: -4 ± 3.9, left tibiofemoral angle: -5.1 ± 4.6) and 7 wi...

متن کامل

Dynamics of a Running Below-Knee Prosthesis Compared to Those of a Normal Subject

The normal human running has been simulated by two-dimensional biped model with 7 segments. Series of normal running experiments were performed and data of ground reaction forces measured by force plate was analyzed and was fitted to some Fourier series. The model is capable to simulate running for different ages and weights at different running speeds. A proportional derivative control algorit...

متن کامل

One Degree-of-freedom Spherical Mechanism Models for Kinematic Analysis of the Human Knee and Ankle Joints

INTRODUCTION In virtually unloaded conditions, the human tibiofemoral (knee) and tibiotalar (ankle) joints behave as single degree-offreedom (1DOF) systems [1]. In these conditions, fibres within the ligaments remain nearly isometric throughout the flexion arc and articular surfaces nearly rigid. Relevant theoretical models are showing that the ligaments and the articular surfaces act together ...

متن کامل

Relationship between workplace ergonomics and musculoskeletal pain, range of motion and spinal deformities in employees: A case study, Kermanshah Oil Refinery

Introduction: Today, the health of human resources in organizations is considered an important arm. This study aimed to investigate the relationship between workplace ergonomics and musculoskeletal pain, joint range of motion (ROM), and spinal deformities in Kermanshah oil refinery staff. Materials and Methods: In the present descriptive-analytical study, all official employees of Kermanshah O...

متن کامل

Mechanical Simulation of the Extension and Flexion of the Elbow Joint in Rehabilitation

Objective: The goal of the present study was to improve the extension and flexion of the elbow joint for rehabilitation purposes, in terms of energy dissipation and of injuries caused by stress imposed on connective tissue by exercise equipments during force transfer , by investigation of viscoelastic property variations during change in speed of motion. Materials & Methods: A sample of five...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic research : official publication of the Orthopaedic Research Society

دوره 33 11  شماره 

صفحات  -

تاریخ انتشار 2015