Fast calculation of fluorescence correlation data with asynchronous time-correlated single-photon counting.
نویسندگان
چکیده
Fluorescence correlation spectroscopy (FCS) is a powerful spectroscopic technique for studying samples at dilute fluorophore concentrations down to single molecules. The standard way of data acquisition, at such low concentrations, is an asynchronous photon counting mode that generates data only when a photon is detected. A significant problem is how to efficiently convert such asynchronously recorded photon count data into a FCS curve. This problem becomes even more challenging for more complex correlation analysis such as the recently introduced combination of FCS and time-correlated single-photon counting (TCSPC). Here, we present, analyze, and apply an algorithm that is highly efficient and can easily be adapted to arbitrarily complex correlation analysis.
منابع مشابه
0.5 billion events per second time correlated single photon counting using CMOS SPAD arrays.
We present a digital architecture for fast acquisition of time correlated single photon counting (TCSPC) events from a 32×32 complementary metal oxide semiconductor (CMOS) single photon avalanche detector (SPAD) array (Megaframe) to the computer memory. Custom firmware was written to transmit event codes from 1024-TCSPC-enabled pixels for fast transfer of TCSPC events. Our 1024-channel TCSPC sy...
متن کاملWide-field Time-correlated Single Photon Counting Microscopy
Time-correlated single photon counting (TCSPC) is a sensitive, robust and precise technique to measure luminescence decays.[1] For fluorescence microscopy, it is often implemented with beam scanning and single point detectors, but we have implemented a camera-based wide-field TCSPC method. We employ a photon counting image intensifier in combination with a 1 MHz frame rate CMOS camera, thus com...
متن کاملCounting photons: from the instruments to the applications
This lectures deals with photon counting in the framework of biophotonic measurements, that are usually characterized by very low count rates. First, photon counting is introduced from an experimental point of view. Then, the main equations of statistics of photon counts are derived, and their consequences in terms of so-called photon or shot noise are discussed. The moment-analysis is introduc...
متن کاملTime-to-Digital Converter card for multichannel time-resolved Single-Photon Counting applications
We present a high performance Time-to-Digital Converter (TDC) card that provides 10 ps timing resolution and 20 ps (rms) timing precision with a programmable full-scale-range from 160 ns to 10 μs. Differential Non-Linearity (DNL) is better than 1.3% LSB (rms) and Integral Non-Linearity (INL) is 5 ps rms. Thanks to the low power consumption (400 mW) and the compact size (78 mm x 28 mm x 10 mm), ...
متن کاملFLCS – Fluorescence Lifetime Correlation Spectroscopy
The fusion of Time-Correlated Single Photon Counting and Fluorescence Correlation Spectroscopy, called Fluorescence Lifetime Correlation Spectroscopy (FLCS), is a method that uses picosecond time-resolved fluorescence detection for separating different FCS-contributions. The main emphasis is on the word separating. FLCS does not involve fitting of a complicated model equation to a complicated a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics express
دوره 11 26 شماره
صفحات -
تاریخ انتشار 2003