Solving the problem of antibody interference in commercial "sandwich"-type immunoassays of carcinoembryonic antigen.
نویسندگان
چکیده
We evaluated the effect of human anti-murine antibodies (HAMA) on apparent concentrations of carcinoembryonic antigen (CEA) as measured in serum with commercial enzyme immunoassay (EIA) kits manufactured by Abbot ("two-step" double monoclonal antibody assay), Roche, and Hybritech (room-temperature protocol). In sera from patients given parenteral murine monoclonal antibody for experimental diagnostic and immunotherapy studies, HAMA titers were determined with Immunomedics' "ImmuSTRIP HAMA-EIA" kit reagents. "True" CEA titers were established by using the ImmuCEA/MA-EIA and heat-extraction to destroy HAMA before assay for CEA. The concordance of the ImmuCEA/MA assay with the Abbott and Roche CEA EIAs was established with sera from normal individuals and from patients who had not received parenteral injections of murine monoclonal antibody. At high (100 mg/L) concentrations of HAMA, false-positive results were observed with all three kits. The Hybritech and Roche assays were more sensitive to interference by HAMA than was the Abbott CEA-EIA, false-positive results being observed at HAMA concentrations between 1 and 10 mg/L. Similar sensitivity of the three kits to interference by primate anti-MAb sera was demonstrated. Use of primate anti-MAb sera to create controls with HAMA activity and of analyte is recommended to evaluate MAb assays for potential HAMA interference and for use to devise methods to eliminate HAMA interference.
منابع مشابه
Murine monoclonal antibody adsorbed onto vinylidene fluoride floccules used to eliminate antibody interference in "sandwich"-type immunoassays.
We have previously reported that human anti-mouse IgG antibody (HAMA) can cause false-positive and false-negative results in "sandwich"-type monoclonal antibody (MAb) assays. To eliminate HAMA interference in "sandwich"-type MAb assays, we investigated the use of MAb on solid-phase, vinylidene fluoride floccules, which we have previously used as a solid-phase second antibody for RIA. The simple...
متن کاملDouble Sandwich ELISA Modified Method for the Detection of Clostridium Botulinum Type E
Background & Objective: A very small amount of botulinum toxin can cause death and on the other hand, there is no cure for its poison other than antitoxin. Therefore, a diagnostic method that can detect very small amounts of botulinum toxin in a short time is very important. In this study, rapid and accurate detection of botulinum toxin type E has been performed with the double sandwich ELISA m...
متن کاملInterference by human anti-mouse antibody in two-site immunoassays.
Studies with goat and rabbit anti-mouse antibody, as models of human anti-mouse antibody (HAMA), have shown that several of the commonly used two -site immunoassays (e.g., for CA-125, carcinoembryonic antigen, choriogonadotropin, lutropin, hepatitis B surface antigen, thyrotropin) are susceptible to interference by this type of bridging heterophile antibody. In most cases the interference can b...
متن کاملValidating a custom multiplex ELISA against individual commercial immunoassays using clinical samples.
The measurement of multiple antigens in a single sample poses clinical and methodological challenges. Here we describe the validation of a multiplexed sandwich enzyme-linked immunosorbent assay (ELISA) array (microELISA) of nine antigens. The antigens tested simultaneously were: alpha-fetoprotein (AFP), prostate specific antigen (PSA), carcinoembryonic antigen (CEA), cancer antigen 125 (CA 125)...
متن کاملDevelopment of an ELISA Test for Detection of Anti FMD Virus Type A87/IRN Antibody Using Irradiated Antigen
Background and Aims: The aim of this study was application of gamma irradiated FMDV antigen for liquid phase blocking sandwich ELISA (B-ELISA) to quantify guinea pig anti FMDV type A87/IRN antibody. Methods: FMDV type A87/IRN was propagated to a titer of 107.5/ml TCID50 and then irradiated by gamma irradiator. The irradiated 146 S antigen was purified by sucrose gradient centrifugation after in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 35 1 شماره
صفحات -
تاریخ انتشار 1989