The effect of milrinone infusion on right ventricular function during coronary anastomosis and early outcomes in patients undergoing off-pump coronary artery bypass surgery
نویسندگان
چکیده
BACKGROUND During coronary anastomosis in off-pump coronary artery bypass surgery (OPCAB), hemodynamic alternations can be induced by impaired diastolic function of the right ventricle. This study was designed to examine the effect of milrinone on right ventricular function and early outcomes in patients undergoing OPCAB. METHODS Forty patients undergoing OPCAB were randomly assigned in a double-blind manner to receive either milrinone (milrinone group, n = 20) or normal saline (control group, n = 20). Hemodynamic variables were measured after pericardiotomy (T1), 5 min after stabilizer application for anastomosis of the left anterior descending coronary artery (LAD, T2), the obtuse marginalis branch (OM, T3), the right coronary artery (RCA, T4), 5 min after sternal closure (T5), and after ICU arrival. The right ventricular ejection fraction (RVEF) and right ventricular volumetric parameters were also measured using the thermodilution technique. For evaluation of early outcomes, the 30-day operative mortality and morbidity risk models were used. RESULTS There was no significant difference in hemodynamic variables, including mean arterial pressure, between the 2 groups, except for the cardiac index and RVEF. The cardiac index and RVEF were significantly greater at T3 in the milrinone group than in the control group. CONCLUSIONS Continuous infusion of milrinone demonstrated a beneficial effect on cardiac output and right ventricular function in patients undergoing OPCAB, especially during anastomosis of the graft to the OM artery, and it had no adverse effect on early outcomes.
منابع مشابه
The Effect of Milrinone on the Right Ventriclular Function in Patients with Reduced Right Ventricular Function Undergoing Off-pump Coronary Artery Bypass Graft Surgery
This investigation evaluated the effect of continuous milrinone infusion on right ventricular (RV) function during off-pump coronary artery bypass graft (OPCAB) surgery in patients with reduced RV function. Fifty patients scheduled for OPCAB, with thermodilution RV ejection fraction (RVEF) <35% after anesthesia induction, were randomly allocated to either milrinone (0.5 microg/kg/min) or contro...
متن کاملComparison of Treatment Outcomes in Off-pump Coronary Artery Bypass Graft and Medical Therapy in Patients with Triple-vessel Coronary Artery Disease and Severe Ventricular Dysfunction
Introduction: Heart failure is a major hazard for public health. Despite recent advance in medical therapy, there is not enough information on the outcome of off-pump coronary artery bypass (OPCAB) and medical therapy on the patients with severe ventricular dysfunction and triple-vessel (CAD). This study aimed to compare treatment outcomes and mortality rate in patients undergoing off-pump coro...
متن کاملPrognostic value of right ventricular myocardial performance index in patients undergoing coronary artery bypass surgery
Abstract Background: Right ventricular myocardial performance index (RVMPI) is a Doppler–derived parameter of non-geometrical ventricular function that measures both systolic and diastolic functions of the right ventricle. The aim of this study is to compare prognostic value of RVMPI with global RV function in patients undergoing Coronary Artery Bypass Graft (CABG). Methods: In a longitudinal ...
متن کاملOn-Pump Beating Coronary Artery Bypass in High Risk Coronary Patients
Background: There are some conflicting results with Conventional Coronary Artery Bypass Grafts (CCABG) with arrested heart in coronary high-risk patients. Moreover, performing off-pump CABG in these cases may be associated with serious complications. The objective of this study is to evaluate the efficacy of the on-pump beating CABG (OPBCABG) in coronary high-risk patients in comparison with th...
متن کاملThe effect of milrinone on the intraoperative hemodynamics during off-pump coronary bypass surgery in patients with an elevated echocardiographic index of the ventricular filling pressure
BACKGROUND Hemodynamic derangement during off-pump coronary artery bypass surgery (OPCAB) is mainly attributed to impaired filling and diastolic dysfunction. An elevated ratio of the mitral velocity to the early-diastolic velocity of the mitral annulus (E/e' > 15) is a relatively new indicator of diastolic function, and this was reported to be associated with impaired hemodynamics during OPCAB....
متن کامل