Surgical Treatment of Midfacial Fracture by Circumzygomatic Wire
ثبت نشده
چکیده
Midfacial ( Le Fort) fractures are types of facial fractures involving the maxillary bone and surrounding structures in a usually bilateral and pyramidal. Incorrect and inappropriate treatment of trauma will end with secondary deformity that is very difficult to correct. Twenty five patients with maxillofacial trauma were seen at Maxillofacial Surgery Department at Ramadi Teaching Hospital including 19(76%) males and 6(24%) females. Road traffic accident and war injuries were the most common cause for facial trauma. Disimpaction of the midface segments was performed manually with Rowe disimpaction forceps and circumzygomatic wire suspension technique was used as method of treatment. In all patients adequate results were achieved with adequate functional and aesthetic outcome.
منابع مشابه
Surgical treatment and a unique management of rostral mandibular fracture with cerclage wire in a horse
A 3-year-old Arabian colt was presented for a major gingiva wound at the right rostral part of mandible. After clinical assessments, rostral mandibular fracture was determined. Stabilization of fractured region was achieved via cerclage wire application under general anesthesia. Fixation wires were left in place for 6 weeks. A 3 -month follow up revealed complete fracture healing. The purpose o...
متن کاملThe use of cerclage wire for surgical repair of unilateral rostral mandibular fracture in horses
Fractures of the rostral mandible in horses are the most common type of jaw fractures. The present study was performed for stabilization of rostral mandibular fracture with cerclage wire. In a retrospective case series, six client-owned horses with unilateral mandibular fractures were admitted to our clinic and suffered from a major gingival wound at rostral part of mandible. Rostral mandibular...
متن کاملIntrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture
Breakage of DHS guide wire during surgery and its migration into the pelvis through the hip joint is a rare complication and its removal can be very challenging for the surgeon. We share our experience of a similar case wherein we used an ‘iliofemoral’ approach to successfully remove the broken transfixing guidewire from the hip joint. Although iliofemoral approach is similar to the lateral win...
متن کاملIntrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture
During fixation of a femoral neck fracture in a 23-year-old male patient with cannulated screws, a broken guide wire fragment inadvertently advanced through the hip joint and protruded into the pelvis. A second surgical approach was needed to remove the broken fragment from the pelvis. Awareness of such a potentially devastating complication will make surgeons more cautious during implementa...
متن کاملClosed K-wire Fixation for the Treatment of Perilunate Dislocation and Trans-Scaphoid Perilunate Fracture Dislocations without Ligamentous Repair: Short Term Follow-Up
Background: The purpose of this study was to evaluate the treatment outcomes of perilunate dislocations (PLDs) andtransscaphoid perilunate fracture dislocations (TSPLDs) treated with operative volar approach without ligament repairor reconstruction.Methods: A total of seven patients (10 hands) were studied during 2017-2018. We fixed scaphoid fractures thorougha volar app...
متن کامل