In vitro assessment of the accuracy of extraoral periapical radiography in root length determination

نویسندگان

  • Muhammad Rizwan Nazeer
  • Farhan Raza Khan
  • Munawwar Rahman
چکیده

OBJECTIVE To determine the accuracy of extra oral periapical radiography in obtaining root length by comparing it with the radiographs obtained from standard intraoral approach and extended distance intraoral approach. MATERIALS AND METHODS It was an in vitro, comparative study conducted at the dental clinics of Aga Khan University Hospital. ERC exemption was obtained for this work, ref number 3407Sur-ERC-14. We included premolars and molars of a standard phantom head mounted with metal and radiopaque teeth. Radiation was exposed using three radiographic approaches: Standard intraoral, extended length intraoral and extraoral. Since, the unit of analysis was individual root, thus, we had a total of 24 images. The images were stored in VixWin software. The length of the roots was determined using the scale function of the measuring tool inbuilt in the software. Data were analyzed using SPSS version 19.0 and GraphPad software. Pearson correlation coefficient and Bland-Altman test was applied to determine whether the tooth length readings obtained from three different approaches were correlated. P = 0.05 was taken as statistically significant. RESULTS The correlation between standard intraoral and extended intraoral was 0.97; the correlation between standard intraoral and extraoral method was 0.82 while the correlation between extended intraoral and extraoral was 0.76. The results of Bland-Altman test showed that the average discrepancy between these methods is not large enough to be considered as significant. CONCLUSIONS It appears that the extraoral radiographic method can be used in root length determination in subjects where intraoral radiography is not possible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In Vitro Comparative Study of the Working Length Determination with Radiovisiography and Conventional Radiography in Dilacerated Canals

Introduction: The aim of this study was to compare digital and conventional radiography in determining the working length of dilacerated canals.Methods: Thirty nine human extracted single-rooted teeth with root curvature more than 35 degrees were included in this study. After access preparation, a file was inserted into the canal and advanced until the file tip was visualized at the foramen. Wi...

متن کامل

In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination

In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination Dr. Hasheminia, S.M.* - Dr. Jafari, N.** *Associate Professor of Endodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Dentist. Abstract Background & Aim: Radiography is still the common method of measuring working length in root canal therapy. While, gag refl...

متن کامل

Comparison of Working Length Determination Using Apex Locator and Conventional Radiography in Curved Canals-an In Vitro Study

Introduction: The exact measurement of the root canal length is of great importance in root canal therapy. Although, determination of the root canal length through radiography is the most common method, recently electronic apex locators are being used to determine working length and decrease the number of radiographs. The purpose of this study was to compare the accuracy of an electronic apex l...

متن کامل

ارزیابی دقت یک نوع Electronic Apex Locator  در تعیین طول دندانهای شیری (In-vitro)

Statement of Problem: Radiography is the most common technique in working length determination, however, because of its limitations is not considered as an ideal technique. Its application, particularly for children due to radiation hazards, technical problems in young and unco-operative children and the superimposition of permanent teeth bud on primary teeth root, lead to numerous problems.Pur...

متن کامل

مقایسه دقت دستگاه‌های اپکس یاب الکترونیکی ZX Root،Novapex  در مقایسه با رادیوگرافی در شرایط in vivo

Background and Aims: Working length determination and remaining this length is of great importance in root canal therapy. Recently, electronic apex locators are being used to determine working length and decrease the number of radiographs. The purpose of this study was to compare the sensitivity of Root ZX and Novapex electronic apex locators with radiography in a clinical study. Materials and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2016