Fuel-cell breathalyser use for field research on alcohol intoxication: an independent psychometric evaluation

نویسندگان

  • Jacob G. Sorbello
  • Grant J. Devilly
  • Corey Allen
  • Lee R.J. Hughes
  • Kathleen Brown
چکیده

Background Several field studies have used fuel-cell breathalysers (FCB) to investigate the prevalence of alcohol intoxication. However, there is a lack of evidence evaluating the psychometric properties of these breathalysers outside of the forensic disciplines. Methods The current research describes four studies designed that assess the reliability and validity of portable platinum FCBs for research on alcohol intoxication. Utilising the Alcolizer LE5 breathalyser and, to a lesser degree, the Lifeloc FC-20 and the Lion Intoxilyzer 8000, each study sampled patrons frequenting popular night-time entertainment districts with varying levels of alcohol intoxication. Results Study one and two found excellent test-retest reliability and inter-instrument reliability for FCBs. Study three and four provided evidence to support the convergent validity of the two FCBs (the LE5 with the FC20), and with an evidential breathalyser (i.e., the Lion Intoxilyzer 8000; EB). Discussion A 93-97% agreement rate between breathalyser readings was found across the four studies. Portable FCB are recommended as a reliable and valid instrument for research designs requiring quick alcohol intoxication estimations in large populations. Strategies to enhance reliable and valid readings are provided for field researchers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fabrication and Evaluation of Pt/M (M= Co, Fe) Chitosan Supported Catalysts for Methanol Electrooxidation: Application in Direct Alcohol Fuel Cell

In this work, Pt, Fe and Co nanoparticles were prepared by chemical reduction of the metal salts in chitosan as the support. NaBH4 was used as the reducing agent Pt-Fe, Pt-Co and Pt-Fe-Co-chitosan nanocomposites were synthesized and characterized by UV–Vis spectra and Transmission electron microscopy images. GC/Pt-chitosan, GC/Pt-Co-chitosan, GC/Pt-Fe-chitosan and GC/Pt-Co-Fe-chitosan electrode...

متن کامل

Diagnostic accuracy study of three alcohol breathalysers marketed for sale to the public

OBJECTIVES To assess the diagnostic accuracy of three personal breathalyser devices available for sale to the public marketed to test safety to drive after drinking alcohol. DESIGN Prospective comparative diagnostic accuracy study comparing two single-use breathalysers and one digital multiuse breathalyser (index tests) to a police breathalyser (reference test). SETTING Establishments licen...

متن کامل

Numerical Modeling of an Innovative Bipolar Plate Design Based on the Leaf Venation Patterns for PEM Fuel Cells

Flow channel design on bipolar plates has a direct effect on Proton Exchange Membrane (PEM) fuel cell performance. It has been found out that the flow field design has a deterministic role on the mass transport and water management, and therefore on the achieved power in PEM Fuel cells. This study concentrates on improvements in the fuel cell performance through optimization of channel dimensio...

متن کامل

Predicting and measuring premises-level harm in the night-time economy.

AIMS To assess associations between measures of premises-level alcohol-related harm and risk factors for harm. METHODS Thirty-two licensed premises with a history of on-premises violent assault were recruited. An environmental survey of the drinking context of each premises was undertaken. Levels of patron intoxication were assessed using a breathalyser and a visual assessment of customers at...

متن کامل

Clinical assessment compared with breathalyser readings in the emergency room: concordance of ICD-10 Y90 and Y91 codes.

OBJECTIVES The purpose of this study was to analyse the validity of clinical assessment of alcohol intoxication (ICD-10 Y91) compared with estimated blood alcohol concentration (BAC) using a breath analyser (ICD-10 Y90) among patients in the emergency room (ER). METHODS Representative samples of ER patients reporting within six hours of injury (n = 4798) from 12 countries comprising the WHO C...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2018