Characterization of continuously distributed cortical water diffusion rates with a stretched-exponential model.
نویسندگان
چکیده
Experience with diffusion-weighted imaging (DWI) shows that signal attenuation is consistent with a multicompartmental theory of water diffusion in the brain. The source of this so-called nonexponential behavior is a topic of debate, because the cerebral cortex contains considerable microscopic heterogeneity and is therefore difficult to model. To account for this heterogeneity and understand its implications for current models of diffusion, a stretched-exponential function was developed to describe diffusion-related signal decay as a continuous distribution of sources decaying at different rates, with no assumptions made about the number of participating sources. DWI experiments were performed using a spin-echo diffusion-weighted pulse sequence with b-values of 500-6500 s/mm(2) in six rats. Signal attenuation curves were fit to a stretched-exponential function, and 20% of the voxels were better fit to the stretched-exponential model than to a biexponential model, even though the latter model had one more adjustable parameter. Based on the calculated intravoxel heterogeneity measure, the cerebral cortex contains considerable heterogeneity in diffusion. The use of a distributed diffusion coefficient (DDC) is suggested to measure mean intravoxel diffusion rates in the presence of such heterogeneity.
منابع مشابه
Comparison of non-Gaussian and Gaussian diffusion models of diffusion weighted imaging of rectal cancer at 3.0 T MRI
Water molecular diffusion in vivo tissue is much more complicated. We aimed to compare non-Gaussian diffusion models of diffusion-weighted imaging (DWI) including intra-voxel incoherent motion (IVIM), stretched-exponential model (SEM) and Gaussian diffusion model at 3.0 T MRI in patients with rectal cancer, and to determine the optimal model for investigating the water diffusion properties and ...
متن کاملIntravoxel water diffusion heterogeneity imaging of human high-grade gliomas.
This study aimed to determine the potential value of intravoxel water diffusion heterogeneity imaging for brain tumor characterization and evaluation of high-grade gliomas, by comparing an established heterogeneity index (alpha value) measured in human high-grade gliomas to those of normal appearing white and grey matter landmarks. Twenty patients with high-grade gliomas prospectively underwent...
متن کاملA Comparison of Two Models of Anomalous Dwi Based on a Known Distribution of Water Diffusion Rates
Introduction: Diffusion-weighted imaging (DWI) signal attenuation in the brain is non-monoexponential [1,2]. Understanding the source of non-monoexponential behavior may lead to an improved characterization of the tissue during disease. Several phenomenological models have been developed to describe this data. Two such models are stretched exponential (αDWI) [3] and second-order cumulant [6] fi...
متن کاملImpacts of the Negative-exponential and the K-distribution modeled FSO turbulent links on the theoretical and simulated performance of the distributed diffusion networks
Merging the adaptive networks with the free space optical (FSO) communication technology is a very interesting field of research because by adding the benefits of this technology, the adaptive networks become more efficient, cheap and secure. This is due to the fact that FSO communication uses unregistered visible light bandwidth instead of the overused radio spectrum. However, in spite of all ...
متن کاملComparison of apparent diffusion coefficients and distributed diffusion coefficients in high-grade gliomas.
PURPOSE To compare apparent diffusion coefficients (ADCs) with distributed diffusion coefficients (DDCs) in high-grade gliomas. MATERIALS AND METHODS Twenty patients with high-grade gliomas prospectively underwent diffusion-weighted MRI. Traditional ADC maps were created using b-values of 0 and 1000 s/mm(2). In addition, DDC maps were created by applying the stretched-exponential model using ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 50 4 شماره
صفحات -
تاریخ انتشار 2003