An Experimental Study of the Implementation of a Fluid Diode Inside a Sano Shunt
نویسندگان
چکیده
Fluid diodes are fluidic devices that enhance fluid flow in a particular direction while inhibiting it in the opposite direction without the use of moving parts. This is accomplished through the use of nozzle shaped geometry on one side of the diode, and cusp shaped geometry on the opposing side. Fluid meets very little resistance as is travels though the nozzle side of the diode. The cusps on the other side of the diode reduce the effective flow area, thereby inhibiting flow. The objective of this study is to determine the effectiveness of a fluid diode installed in a reconstructed cardiovascular system of an infant diagnosed with hypoplastic left heart syndrome. The fluid diode is not used inside the heart, but rather inside a shunt connecting the ventricle to the pulmonary artery. Currently, patients are experiencing regurgi-tant blood flow inside this shunt, which is known as a Sano shunt. This regurgitant volume increases the workload of the ventricle, which can lead to myocardial hyper-trophy and eventual cardiac failure [1, 2]. The principle objective of this thesis is to characterize the performance of certain diodes by testing them experimentally using a mock circulatory system. Experiments were performed on three different size diodes-in-shunts as well as three different size empty shunts. The data from each diode-in-shunt test was compared to the data from each empty shunt test in order to determine if any performance gain was present. The regurgitant fraction (RF%) as well as the individual systolic and diastolic flow volumes were used to evaluate the performance of both the diodes-in-shunts as well as the empty shunts. The earlier experiments were conducted with the diode situated in the middle of the shunt. By moving the diode to the entrance of the shunt, the RF% was improved by as much as 51%. However, with only three different size diodes-in-shunts as well as three different size empty shunts available for testing, it is hard to draw any definitive conclusions as to whether or not a diode can maintain the same systolic flow levels while reducing diastolic flow levels. Further testing using different diameter diodes is required.
منابع مشابه
Evaluation of the Effects of Injection Velocity and Different Gel Concentrations on Nanoparticles in Hyperthermia Therapy
Background and objective: In magnetic fluid hyperthermia therapy, controlling temperature elevation and optimizing heat generation is an immense challenge in practice. The resultant heating configuration by magnetic fluid in the tumor is closely related to the dispersion of particles, frequency and intensity of magnetic field, and biological tissue properties.Methods: In this study, to solve he...
متن کاملAirflow inside tunnel boring machine: A numerical study and an experimental verification
Knowledge of the airflow distribution inside a Tunnel Boring Machine (TBM) can create a safe working environment for workers and machinery. The airflow quality and the related mass flow rate in the ventilation system should be sufficient to dilute gases and remove dust inside the tunnel. In this work, airflow distribution in the single shield TBM tunnel was studied using computational fluid dyn...
متن کاملInvestigation of fluid flow and heat transfer in tube hot metal gas forming process
In this study, hot metal gas forming process of AA6063aluminumtubeis studied with a focus on heat transfer of both fluid and solid phases numerically. An experimental study is simultaneously conducted to validate the numerical method. Some of the most important outputs of the present study, are velocity distribution of fluid inside the tube as well as the fluid in the gap between tube and matri...
متن کاملExperimental Investigation of Mixed Convection Heat Transfer in Vertical Tubes by Nanofluid: Effects of Reynolds Number and Fluid Temperature
An experimental investigation was carried out to study mixed convection heat transfer from Al2O3-water nanofluid inside a vertical, W-shaped, copper-tube with uniform wall temperature. The tests covered different ranges of some involved parameters including Reynolds number, temperature and particles volume fraction. The results showed that the rate of heat transfer coefficient improved with Rey...
متن کاملDesign and Implementation of a New Switch-Diode based Single Source Multilevel Inverter Topology
Multilevel inverters are a new generation of DC-AC converters at medium and high voltage and power levels. These converters have made great strides in the use of industrial applications compared to conventional two-level inverters due to lower harmonic distortion, filter size, EMI and dv/dt. Besides these merits, some disadvantages can be mentioned such as more power electronics devices and com...
متن کامل