Acute left ventricle diastolic function improvement after transcatheter aortic valve implantation.
نویسندگان
چکیده
AIMS Data regarding the effects of TAVI on LV after are scarce and conflicting results have been reported immediately after aortic valvuloplasty. This study aimed to determine the acute haemodynamic effects of transcatheter aortic valve implantation (TAVI) in left ventricle (LV) diastolic performance, immediately after aortic valvuloplasty and prosthesis deployment. METHODS AND RESULTS Sixty-one patients with severe aortic valve stenosis, and preserved LV systolic function submitted to successful TAVI, were included. All procedures were guided through transoesophageal echocardiography, and parameters of diastolic function were evaluated before and minutes after TAVI. The mean age was 83.5±6 years and mean log EuroSCORE was 18.2±9.4. Before the procedure, all patients presented LV diastolic dysfunction. Immediately after TAVI, fewer patients presented a restrictive pattern [27 (44.3%), before the procedure, vs. 20 (34.4%), after TAVI (P=0.047)], and an increase in E wave deceleration time (211.2±75.5 vs. 252.7±102.3 cm/s, P=0.001), in E wave velocity (109.5±41.2 vs. 120.3±43.6 cm/s, P=0.025), and in isovolumetric relaxation time (83±36.5 vs. 97.1±36.0 ms, P=0.013) was observed. On multivariate analysis of covariance (ANCOVA), adjusting to LV systolic function, heart rate, blood pressure, and haematocrit values, the results remained significant. Patients referred to percutaneous approach had invasive haemodynamic data collected, showing a decrease in LV end-diastolic pressure after valve implantation [18.8±5.7 vs. 14.7±4.7, mean difference -4.1 (95% CI: -5.9; -2.9)]. Patients with a restrictive pattern immediately after TAVI presented a smaller decrease in LV end diastolic pressure (-3.3±4.7) than those with diastolic dysfunction grade I or II (-9.5±4.7; P=0.017). CONCLUSION This is the first study describing LV diastolic performance during TAVI. Our results show improvement in diastolic function parameters in patients with preserved LV systolic function, immediately after successful TAVI.
منابع مشابه
A classic yet unusual case: the full spectrum of bicuspid aortic valve disease.
Circulation 2010;122:1928–36. 36. Goncalves A, Marcos-Alberca P, Almeria C, Feltes G, Rodriguez E, HernandezAntolin RA et al. Acute left ventricle diastolic function improvement after transcatheter aortic valve implantation. Eur J Echocardiogr 2011;12:790–7. 37. Oxborough D, Whyte G, Wilson M, O’Hanlon R, Birch K, Shave R et al. A depression in left ventricular diastolic filling following prolo...
متن کاملAcute regional improvement of myocardial function after interventional transfemoral aortic valve replacement in aortic stenosis: A speckle tracking echocardiography study
BACKGROUND Transcatheter aortic valve implantation (TAVI) is a promising therapy for patients with severe aortic stenosis (AS) and high perioperative risk. New echocardiographic methods, including 2D Strain analysis, allow the more accurate measurement of left ventricular (LV) systolic function. The goal of this study was to describe the course of LV reverse remodelling immediately after TAVI i...
متن کاملImmediate recovery of the left atrial and left ventricular diastolic function after transcatheter aortic valve implantation: A transesophageal echocardiography study.
BACKGROUND Chronic increased afterload due to severe aortic stenosis (AS) results in com-pensatory concentric left ventricular (LV) hypertrophy and LV dysfunction. These in turn cause remodeling of the left heart. The aim of this study was to investigate the acute effect of transcatheter aortic valve implantation (TAVI) on left atrial (LA) mechanics and LV diastolic function. METHODS The stud...
متن کاملShort-term effects of transcatheter aortic valve implantation.
BACKGROUND Aortic stenosis (AS) leads to remodeling of the left heart. Strain measurements enable the assessment of left atrial (LA) mechanics. The goal of this study was to evaluate the short-term effects of transcatheter aortic valve implantation (TAVI) on LA myocardial deformation as well as left ventricular (LV) diastolic function. METHODS Thirty-two patients with severe AS were prospecti...
متن کاملSurgical Bailout Therapy after Implantation of a Medtronic CoreValve Bioprosthesis
Moderate-to-severe paraprosthesic leak causing hemodynamic deterioration and left ventricular remodeling can occur after transcatheter aortic valve implantation (TAVI). We present the case of a 75-year-old woman who underwent TAVI with a 26 mm CoreValve prosthesis complicated with an acute left ventricle dilatation due to a severe paravalvular leak. Patient was unresponsive to elective balloon ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology
دوره 12 10 شماره
صفحات -
تاریخ انتشار 2011