Detection of experimental pulmonary emboli in dogs by sequential positron imaging after inhalation of 15O-carbon dioxide.
نویسندگان
چکیده
After inhalation, C15O2 (T1/2 = 2 minutes) rapidly diffuses into pulmonary blood and is cleared from the lungs within 10 seconds. The purpose of this study was to determine whether impaired clearance of inhaled C15O2 from oligemic zones, distal to areas of obstructed pulmonary blood flow, could be detected by serial pulmonary imaging with a positron camera. Experimental obstruction of branches of the pulmonary artery was induced in 19 anesthetized dogs by inflation of balloon-tipped catheters (8-12 mm in diameter), injection of radiopaque silicone spheres (0.5-4.0 mm), and embolization with barium-impregnated autologous blood clots (1-5 mm) via the right external jugular vein. After a single bolus injection of 2 mCi of C15O2 into the endotracheal tube, serial lung images of 15O activity were obtained over 60-180 seconds. Obstruction of pulmonary arterial branches resulted in visualization of discrete zones of impaired 15O clearance which varied in area with catheter diameter. Location and size of these zones were confirmed by repeat imaging after direct injection of 15O-labeled blood through the distal catheter lumen. In dogs receiving autologous clots (n = 8), similar zones of impaired 15O clearance were consistently imaged, and single emboli as small as 2 mm in diameter produced regions of retained 15O activity. Zones of retained 15O activity corresponded to the location of radiopaque emboli on chest radiographs. This study introduces a new technique of radionuclide imaging for detection of pulmonary emboli that is noninvasive, safe, sensitive, and repeatable at short intervals.
منابع مشابه
Detection of Experimental Pulmonary Emboli in Dogs by Sequential Positron Imaging after Inhalation of O-Carbon Dioxide
Copyright © 1978 American Heart Association. All rights reserved. Print ISSN: 0009-7330. Online ISSN: TX 72514 Circulation Research is published by the American Heart Association. 7272 Greenville Avenue, Dallas, 1978;42;53-63 Circ. Res. AB Nichols, S Cochavi, RH Moore and GA Beller imaging after inhalation of 15O-carbon dioxide Detection of experimental pulmonary emboli in dogs by sequential po...
متن کاملInhalation imaging with oxygen-15 labeled carbon dioxide for detection and quantitation of left-to-right shunts.
Quantitation of left-to-right shunts was determined noninvasively from the pulmonary clearance pattern of inhaled 15oxygen-labeled carbon dioxide (C15O2). After a single breath inhalation of C15O2, counts over the lungs were obtained from sequential 0.5 sec positron camera images. In 21 patients without left-to-right shunts, counts declined exponentially due to the washout of C15O2 by the pulmo...
متن کاملNoninvasive quantification of regional myocardial blood flow in coronary artery disease with oxygen-15-labeled carbon dioxide inhalation and positron emission tomography.
BACKGROUND Oxygen-15-labeled water is a diffusible, metabolically inert myocardial blood flow tracer with a short half-life (2 minutes) that can be used quantitatively with positron emission tomography (PET). The purpose of this study was to validate a new technique to quantify myocardial blood flow (MBF) in animals and to assess its application in patients. METHODS AND RESULTS The technique ...
متن کاملPositron imaging of cerebral blood flow during continuous inhalation of C15O2.
This investigation tests the hypothesis that the normal cerebral image obtained non-invasively during continuous inhalation of C15O2 is related to cerebral blood flow. Trace amounts of CO2 labeled with the positron-emitting radionuclide 15O were administered to 4 normal subjects at normo- and hypocapnia and to 2 of these subjects at hypercapnia. Hypocapnia typically caused a marked decrease in ...
متن کاملAssessment of regional myocardial blood flow and regional fractional oxygen extraction in dogs, using 15O-water and 15O-hemoglobin.
A new approach to the assessment of regional myocardial blood flow and fractional oxygen extraction has been developed using 15O-water (H2-15O) and 15O-hemoglobin (15O-Hb). Bolus doses (1 mCi) of H2-15O and 15O-Hb were injected 10 minutes apart into the left main coronary artery of 12 normal dogs. Sequential images of regional myocardial tracer clearance were obtained over 5 minutes with a posi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation research
دوره 42 1 شماره
صفحات -