Morphological analysis of apical foramen over-instrumented by three rotary NiTi systems.

نویسندگان

  • Zong Xiang Liu
  • Yi Liu
  • Jeffrey Ww Chang
  • Chang Yong Yuan
  • Cheng Fei Zhang
  • Peng Lai Wang
چکیده

OBJECTIVE To evaluate morphological changes of the apical surface after root canal preparation with 1 mm beyond the apical foramen using ProTaper Universal (PTU) files, K3 files and Twisted files (TF), respectively. METHODS Seventy teeth with a centered apical foramen and 70 teeth with a deviated apical foramen were included as group A and group B respectively. In each group, 20 teeth were randomly assigned for root canal preparation with PTU, K3 and TF files, respectively; the remaining 10 teeth were used as the control group without any preparation. The apical foramens were examined with scanning electronic microscopy. The foramen integrity damage (FID) and dentin defects (DDs) were noted and compared between different groups. RESULTS FID and DD were significantly less in Group A. DDs was not found in the control group. Preparation with PTU, K3, and TF files caused FID in 6.67%, 10%, and 3.33% of teeth in the group A, and in 20%, 26.67%, and 10% in Group B, respectively. Preparation with PTU, K3, and TF files caused DD in 6.67%, 6.67%, and 3.33% of teeth in Group A, and in 23.33%, 26.67%, and 6.67% in Group B, respectively. PTU and K3 files produced more DDS than TF files. However, no significant difference was found between groups using PTU and K3 files. CONCLUSION Rotary instrumentation caused less damage on the apical surface in foramencentered root canals than foramen-deviated root canals when working beyond the canal length. TF files had a tendency to produce less DDS compared with PTU or K3 files during over-instrumented root canals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparative Study on the Amount of Extruded Material from the Apical Foramen with NiTi Rotary and Stainless Steel Hand Instruments

INTRODUCTION The purpose of the present study was to quantify and compare the amount of extruded debris from apical foramen after instrumentation of the root canal system with hand and rotary instruments. MATERIALS AND METHODS Root canals of forty five fresh extracted single rooted human teeth with mature apexes and less than 15 degree of root curvature were instrumented in group A with stain...

متن کامل

Comparison of apical transport in three rotary systems and one modified technique

Comparison of apical transport in three rotary systems and one modified technique Dr. A.R. Farhad* - Dr. H. Bakhtiar*** - Assistant Professor of Endodontics Dept. - Faculty of Dentistry – Isfahan University of Medical Sciences. **- Endodontist. Background and Aim: Procedural errors such as canal transportation and loss of working length are mainly associated with stainless steel files with insu...

متن کامل

Apical extrusion of bacteria when using reciprocating single-file and rotary multifile instrumentation systems.

AIM To evaluate ex vivo, apical bacterial extrusion associated with two reciprocating single-file systems (WaveOne and Reciproc) compared with a conventional multifile rotary system (BioRace). METHODOLOGY Forty-five human single-rooted mandibular incisors were used. Endodontic access cavities were prepared, and root canals were contaminated with an Enterococcus faecalis suspension. Following ...

متن کامل

Evaluation Of Apical Transportation Using 3 Different Rotary Systems: Hyflex Files, Twisted Files, Protaper Next By Morphometric Analysis

Aim: This in vitro study was performed to evaluate the apical transportation between Hyflex files, Twisted files and Protaper next single file rotary system by motic imaging. Materials & Methods: Sixty Endo Training Blocks were used in the study. Pre instrumentation photos of the simulated apical foramen are recorded using an optical microscope and then coupled into the motic imaging software a...

متن کامل

Evaluation of three instrumentation techniques at the precision of apical stop and apical sealing of obturation

OBJECTIVE The aim of this study was to investigate the ability of two NiTi rotary apical preparation techniques used with an electronic apex locator-integrated endodontic motor and a manual technique to create an apical stop at a predetermined level (0.5 mm short of the apical foramen) in teeth with disrupted apical constriction, and to evaluate microleakage following obturation in such prepare...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Chinese journal of dental research : the official journal of the Scientific Section of the Chinese Stomatological Association

دوره 17 2  شماره 

صفحات  -

تاریخ انتشار 2014