Validation of pressure gradient and peripheral fractional flow reserve measured by a pressure wire for diagnosis of iliofemoral artery disease with intermediate stenosis
نویسندگان
چکیده
OBJECTIVE To examine the pressure gradient and peripheral fractional flow reserve (pFFR) measured by a pressure wire as indicators of hemodynamic significance in iliofemoral angiographic intermediate stenosis. BACKGROUND The utility of pressure measurements using a pressure wire with vasodilators is unclear in cases with intermediate iliofemoral stenosis. METHODS The mean pressure gradient (MPG) and mean pressure ratio (MPR) were measured at baseline and after injection of isosorbide dinitrate in 23 lesions with angiographically intermediate iliofemoral stenosis. Patients with complex lesions, infrapopliteal artery lesions, chronic total occlusion, and surgical bypass grafts were excluded. Hyperemic MPR was considered equivalent to pFFR. Changes in parameters in response to vasodilators were assessed and correlations of peak systolic velocity ratio (PSVR) with hyperemic MPG and pFFR were examined using duplex ultrasound. RESULTS After injection of isosorbide dinitrate, hyperemic MPG increased significantly (from 9.0±5.7 to 16.3±6.2 mmHg; P<0.05) and hyperemic MPR (pFFR) decreased significantly (from 0.92±0.06 to 0.81±0.07; P<0.05). PSVR was significantly correlated with hyperemic MPG (R=0.52; P<0.05) and pFFR (R=-0.50; P<0.05). The optimal cut-off value of pFFR as an indicator of significant hemodynamic stenosis (PSVR >2.5) was 0.85 (area under the curve 0.72; sensitivity 94%; specificity 50%, P<0.05). CONCLUSION pFFR measured using a pressure wire is reliable for prediction of hemodynamic significance in iliofemoral intermediate stenosis.
منابع مشابه
Pressure gradient measurement using phase contrast (PC)-MRI in stenotic phantom models: Towards noninvasive quantification of fractional flow reserve in the coronary arteries
Background Fractional flow reserve (FFR) is an invasive diagnostic tool to evaluate the functional significance of an intermediate coronary stenosis by quantifying the pressure gradient (ΔP) across that stenosis [1]. Noninvasive ΔP measurement (ΔPMR) using phase-contrast (PC)-MRI in conjunction with Navier-Stokes (NS) equations has been attempted in large to medium size vessels [2-4], and recen...
متن کاملUtilization of translesional hemodynamics: comparison of pressure and flow methods in stenosis assessment in patients with coronary artery disease.
Aim of this study is the assessment of feasibility and clinical usefulness of a new index of stenosis severity, the slope of the instantaneous transstenotic pressure gradient/velocity relationship. Twenty-one patients scheduled for percutaneous revascularization procedures were studied with simultaneous measurement of poststenotic coronary pressure and flow velocity, in basal condition and duri...
متن کاملExperimental Basis of Determining Maximum Coronary, Myocardial, and Collateral Blood Flow by Pressure Measurements for Assessing Functional Stenosis Severit Before and After Percutaneous Transluminal Coronary Angioplasty
Background. Severity of coronary artery stenosis has been defined in terms of geometric dimensions, pressure gradient-flow relations, resistance to flow and coronary flow reserve, or maximum flow capacity after maximum arteriolar vasodilation. A direct relation between coronary pressure and flow, however, may only be presumed if the resistances in the coronary circulation are constant (and mini...
متن کاملPressure gradient measurement in the coronary artery using phase contrast (PC)-MRI: initial patient results towards noninvasive quantification of fractional flow reserve
Background Fractional flow reserve (FFR) is an invasive procedure evaluating the functional significance of an intermediate coronary stenosis in patients with coronary artery disease (CAD) [1]. Quantification of pressure gradient (ΔP) across a particular stenosis is the key to the determination of FFR. Noninvasive ΔP measurement (ΔPMR) using phase-contrast (PC)-MRI in conjunction with NavierSto...
متن کاملPressure gradient measurement in the coronary artery using 4D PC-MRI: towards noninvasive quantification of fractional flow reserve
Background Fractional flow reserve (FFR) is an invasive procedure evaluating the functional significance of an intermediate stenosis by measurement of pressure drop across stenosis [1]. Noninvasive pressure measurement technique i.e. Phase-contrast (PC)-MRI has been studied in the cardiac chamber[2], aorta[3], and renal[4] arteries. The purpose of this study was to investigate the feasibility o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 8 شماره
صفحات -
تاریخ انتشار 2015