Measurements of the Weak UV Absorptions of Isoprene and Acetone at 261–275 nm Using Cavity Ringdown Spectroscopy for Evaluation of a Potential Portable Ringdown Breath Analyzer
نویسندگان
چکیده
The weak absorption spectra of isoprene and acetone have been measured in the wavelength range of 261-275 nm using cavity ringdown spectroscopy. The measured absorption cross-sections of isoprene in the wavelength region of 261-266 nm range from 3.65 × 10⁻²¹ cm².molecule⁻¹ at 261 nm to 1.42 × 10⁻²¹ cm².molecule⁻¹ at 266 nm; these numbers are in good agreement with the values reported in the literature. In the longer wavelength range of 270-275 nm, however, where attractive applications using a single wavelength compact diode laser operating at 274 nm is located, isoprene has been reported in the literature to have no absorption (too weak to be detected). Small absorption cross-sections of isoprene in this longer wavelength region are measured using cavity ringdown spectroscopy for the first time in this work, i.e., 6.20 × 10⁻²³ cm².molecule⁻¹ at 275 nm. With the same experimental system, wavelength-dependent absorption cross-sections of acetone have also been measured. Theoretical detection limits of isoprene and comparisons of absorbance of isoprene, acetone, and healthy breath gas in this wavelength region are also discussed.
منابع مشابه
A Portable Real-Time Ringdown Breath Acetone Analyzer: Toward Potential Diabetic Screening and Management
Breath analysis has been considered a suitable tool to evaluate diseases of the respiratory system and those that involve metabolic changes, such as diabetes. Breath acetone has long been known as a biomarker for diabetes. However, the results from published data by far have been inconclusive regarding whether breath acetone is a reliable index of diabetic screening. Large variations exist amon...
متن کاملBreath Analysis Using Laser Spectroscopic Techniques: Breath Biomarkers, Spectral Fingerprints, and Detection Limits
Breath analysis, a promising new field of medicine and medical instrumentation, potentially offers noninvasive, real-time, and point-of-care (POC) disease diagnostics and metabolic status monitoring. Numerous breath biomarkers have been detected and quantified so far by using the GC-MS technique. Recent advances in laser spectroscopic techniques and laser sources have driven breath analysis to ...
متن کاملInfrared Cavity Ringdown Spectroscopy of the Water Cluster Bending Vibrations
We report the first measurement of water monomer bending vibrations in gaseous (H2O)n clusters. Infrared cavity ringdown spectroscopy reveals discrete and sequentially blue-shifted bands near 6 μm for n ) 2-4 and unresolved broad features for n > 4, supporting both theoretical predictions and solid-state spectroscopy results. These measurements provide a measure of the monomer distortion that a...
متن کاملTrace species detection in the near infrared using Fourier transform broadband cavity enhanced absorption spectroscopy: initial studies on potential breath analytes.
Cavity enhanced absorption measurements have been made of several species that absorb light between 1.5 and 1.7 µm using both a supercontinuum source and superluminescent light emitting diodes. A system based upon an optical enhancement cavity of relatively high finesse, consisting of mirrors of reflectivity ∼99.98%, and a Fourier transform spectrometer, is demonstrated. Spectra are recorded of...
متن کاملCavity ringdown laser absorption spectroscopy and time-of-flight mass spectroscopy of jet-cooled copper silicides
The cavity ringdown technique has been implemented for electronic spectroscopy of jet-cooled CuSi produced in a pulsed UV laser vaporization plasma reactor. A time-of-flight mass spectrometer is used to simultaneously monitor species produced in the supersonic expansion and allows correlation studies to be performed. Seven rotationally resolved vibronic bands have been measured near 400 nm, yie...
متن کامل