Diagnostic and Interventional Radiology: a Stradegy for Introducing Diagnistic Reference Levels Taking into Account the National Practice
نویسندگان
چکیده
Diagnostic reference levels (DRLs) are difficult to define in the case of X-ray examinations involving fluoroscopy particularly those performed in angiography and interventional radiology due to the large variability between examinations: fluoroscopy duration, number of images, image quality required. In order to tackle this problem a nation-wide dosimetric survey was performed in Switzerland involving five university hospitals, aiming at establishing a set of DRLs for eight types of examinations performed in diagnostic and interventional radiology. Each centre was requested to provide information on the patients and the technical data related to 20 examinations for each type. From the data collected, the distributions of the dose-area product, the number of images and the duration of fluoroscopy were established. A large variability of the technique was found. A set of DRL values was then determined using the 3rd-quartile method. These results will be sent to the radiologists to be analysed accompanied with some proposals for dose reduction.
منابع مشابه
Diagnostic Reference Levels for Computed Tomography Examinations in Iran: A Nationwide Radiation Dose Survey
Introduction: International Commission on Radiological Protection introduced three basic principles of radiation protection, namely justification, optimization, and dose limit. Medical exposure has no dose limits, and generally, diagnostic reference levels are used as a tool for optimization of patient protection. Material and Methods: Dosimetry was performed on 20 CT scanners located in 14 cit...
متن کاملRadiation Protection in Interventional Radiology
Interventional procedures are used by a significant number of medical specialities. Radiation protection (RP) for patients and staff is one of the main issues in Interventional Radiology (IR). UNSCEAR, ICRP and IAEA have devoted significant time over the last years to improve radiation safety in IR. Several combined factors: prolonged localized fluoroscopy, multiple radiographic exposures, and ...
متن کاملDiagnostic Reference Level of Computed Tomography Examinations and Need for Dose Optimization in Ondo State, Nigeria
Introduction: The present study was conducted to obtain State diagnostic reference levels (DRLs) of five routine computed tomography (CT) examinations from two CT centers in Ondo State and to identify factors responsible for dose variation and escalation in these CT centers. Material and Methods: Acquisition parameters and CT dose indices wer...
متن کاملA local study on diagnostic reference levels estimation for children computed tomography
Introduction: The Diagnostic reference levels (DRLs) play a critical role in the optimization of radiation dose especially, in some conditions like pediatrics. They are useful indicators by which the radiologists can be aware of delivered excess radiation doses to the patients, and take corrective actions if necessary. In order to meet some requirements for establishing the nat...
متن کاملThe need for national diagnostic reference levels: Entrance surface dose measurement in intraoral radiography
Background: Intraoral radiographies are the most frequent X-ray examinations in humans. According to International Commission on Radiation Protection (ICRP) recommendations, the selection of a diagnostic reference level (DRL) should be specific to a country or region. Critica l organs such as thyroid gland are exposed to X-rays in intraoral radiography and these exposures should be kept as low ...
متن کامل