A laboratory study comparing skin temperature and fluid loss on air-fluidized therapy, low-air-loss, and foam support surfaces.

نویسنده

  • Charles Lachenbruch
چکیده

To ensure appropriate fluid replacement, caregivers need to understand the effect of support surfaces on the rate of moisture loss from the body. A prospective study was conducted to 1) measure the rate of weight (fluid) loss on an air-fluidized therapy (AFT) surface; 2) determine the effect of bath temperature on weight loss; 3) compare weight loss and skin temperatures between foam and low-air loss (LAL) surfaces; 4) compare characteristics of individuals with high and low weight loss rates; and 5) compare weight loss rates to previously measured rates of support surface evaporative capacity. Eight healthy adult volunteers (three men, five women, average age 33 years, average body mass index 31.0 kg/m²) participated in eight 180-minute trials (one trial per day) on a foam, an LAL, and an AFT surface at five different bath temperatures (range: ~99.0 °F [hot] to ~88.0 °F [low]). Weight (± 10 g) was obtained before and after each trial and skin temperature (across the back) was recorded continuously. Using linear regression, weight loss rate on AFT was found to be strongly dependent upon bath temperatures: weight loss/day (g/m²-24 hours) = 53.9 x T (F) - 4030, where T is the mean skin temperature on the patient's back (also equal to bath temperature) in (F) Fahrenheit. Using this regression equation at mid-range (94 °F), fluid loss in an average woman (145 lb/64.5 inches/1.72 m² body surface area [BSA]) on AFT would be estimated to be 850 g/day higher than on foam. Compared with LAL, weight loss on AFT was estimated to be 700 g/day and 800 g/day higher for the typical woman and man, respectively (P < 0.05 at a mid-range bath temperature of 94 °F). Weight loss rates varied from 480 g/m²-24 hours to 3,470 g/m²-24 hours. Weight loss and mattress evaporative rates also suggest that moisture accumulation may occur on a foam but not on an LAL or AFT surface. However, fluid intake should be increased on AFT, particularly when bath temperature settings are high.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation test for climate control on air-loss supports.

OBJECTIVE To develop a simple, reproducible validation test protocol for classification of air-loss support systems. DESIGN Simultaneous experimental measurement of moisture loss and temperature reduction at the air-loss support surface-human body equivalent interface from a sweating human skin analogue. SETTING A hospital department of physical medicine and rehabilitation. OTHER PARTICIP...

متن کامل

Evaluation of Eulerian Two-Fluid Numerical Method for the Simulation of Heat Transfer in Fluidized Beds

Accurate modeling of fluidization and heat transfer phenomena in gas-solid fluidized beds is not solely dependent  on the particular selected numerical model and involved algorithms. In fact, choosing the right model for each specific operating condition, the correct implementation of each model, and the right choice of parameters and boundary conditions, determine the accuracy of the results i...

متن کامل

"Constant force technology" versus low-air-loss therapy in the treatment of pressure ulcers.

"Least costly but most effective" has never been more important to healthcare delivery than in the current healthcare environment of changing reimbursement systems. In wound care, the high costs associated with renting advanced support surfaces may be an area where expenses can be decreased if similar outcomes can be attained by using more affordable mattresses. This article compares the healin...

متن کامل

Experimental study and application of computational fluid dynamics on the prediction of air velocity and temperature in a ventilated chamber

The shape of the air flow in the interior is heavily influenced by the air distribution system and the way air enters and exits. By numerically simulating flow by computational fluid dynamics, one can determine the flow pattern and temperature distribution and, with the help of the results, provide an optimal design of the air conditioning system. In this study, a chamber was first constructed ...

متن کامل

Investigation of combined effects of noise and low air temperature on human-environmental comfort and physiological responses- An experimental study

Background and Aim: Combined exposure to noise and temperature can affect the neurophysiological responses of the office staff. The present study was done to investigate the impacts of combined exposure to noise and low air temperature on physiological responses and environmental comfort. Methods: In this experimental study, the studied population included the students who were randomly selecte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ostomy/wound management

دوره 56 8  شماره 

صفحات  -

تاریخ انتشار 2010