Safe zone for transacetabular screw fixation in prosthetic acetabular reconstruction of high developmental dysplasia of the hip.

نویسندگان

  • Q Liu
  • Y X Zhou
  • H J Xu
  • J Tang
  • S J Guo
  • Q H Tang
چکیده

BACKGROUND Prosthetic reconstruction of hips with Crowe type-IV developmental dysplasia (a high complete dislocation) is technically demanding. Insufficient osseous coverage and osteopenic bone stock frequently necessitate transacetabular screw fixation to augment primary stability of the metal acetabular shell. We sought to determine whether a previously reported quadrant system for screw fixation of the acetabular cup can be applied in patients with high dislocation of the hip and to define a specialized safe zone for screw fixation in these hips, if needed. METHODS Using volumetric computed tomographic data and image-processing software, we made three-dimensional reconstructions of the osseous and vascular structures in eighteen hips in twelve patients. We virtually reconstructed a cup in the true acetabulum and dynamically simulated transacetabular screw fixation. We mapped the hemispheric cup into several areas and, for each, measured the distance between the virtual screw and the external iliac (femoral) and obturator blood vessels. In the six patients with unilateral high dislocation of the hip and a relatively normal, contralateral hip, the six relatively normal hips served as controls. RESULTS Reconstruction of the cup at the level of the true acetabulum shifted the center of rotation anteroinferiorly in the hips with a high, complete dislocation. Screws guided by the quadrant system frequently injured the obturator blood vessels in the hips with a high dislocation. In these patients, the safe zone shifted as a result of moving the prosthetic cup. CONCLUSIONS The quadrant system, although helpful in determining screw placement in hips with a normal center of rotation, can be misleading and of less value in guiding screw insertion to augment acetabular shells for hips with a high dislocation. We believe that a safe zone specific to hips with a high dislocation should be used to guide transacetabular screw fixation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reconstruction of the Acetabulum in Developmental Dysplasia of the Hip in Total Hip Replacement

Developmental dysplasia of the hip (DDH) or congenital hip dysplasia (CDH) is the most prevalent developmental childhood hip disorder. It includes a wide spectrum of hip abnormalities ranging from dysplasia to subluxation and complete dislocation of the hip joint. The natural history of neglected DDH in adults is highly variable. The mean age of onset of symptoms is 34.5 years for dysplastic DD...

متن کامل

Total hip replacement for developmental dysplasia of the hip.

Total hip arthroplasty relieves pain and improves function for many patients with endstage arthritis secondary to developmental dysplasia of the hip. Acetabular dysplasia, however, presents a special problem for total hip reconstruction in these patients. Structural bone grafting with femoral head autografting to the dysplastic acetabulum and cementing acetabular components into the graft provi...

متن کامل

Acetabular anatomy and the transacetabular fixation of screws in total hip arthroplasty.

An anatomical and radiographic study was undertaken to determine the safest zones in the acetabulum for the transacetabular placement of screws during uncemented acetabular arthroplasty. To avoid injury to intrapelvic structures, which are not visible to the surgeon during placement of the screws, cadavera were studied to define the location of these structures with respect to fixed points of r...

متن کامل

پارامترهای آناتومیک مفصل هیپ و ارتباط آن‌ها با پارامترهای فیزیکی بدن

Background and Objective: Arthrosis of the hip joint is one of the most common complications of patients and many efforts have been made to find its etiology. One of the subjects important for researchers is morphologic parameters of the hip joint and its relationship with osteoarthritis of this joint. Since these parameters themselves are affected by physical parameters of the body and the rac...

متن کامل

Clinical Results of Percutaneous Fixation of Pelvic and Acetabular Fractures: A Minimally Invasive Internal Fixation Technique

Background: The pelvic ring fractures (PRF) and acetabular fractures (AF) are among the major orthopedic injuriesassociated with high rates of morbidity and mortality. Open surgical stabilization is the standard treatment for themajority of these complications. Percutaneous minimally invasive surgical stabilization of the fractures has become anaccepted treatment method for th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. American volume

دوره 91 12  شماره 

صفحات  -

تاریخ انتشار 2009