Hemodynamic Parameters of Low-Flow Isoflurane and Low-Flow Sevoflurane Anesthesia During Controlled Ventilation With Laryngeal Mask Airway

نویسندگان

  • Sohrab Negargar
  • Ali Peirovifar
  • Ata Mahmoodpoor
  • Masoud Parish
  • Samad EJ Golzari
  • Haniye Molseqi
  • Soheil Negargar
چکیده

BACKGROUND Nowadays laryngeal mask airway (LMA) is popular as one of the best choices for airway management. Low-flow anesthesia has some advantages like lower pollution, hemodynamic stability and cost effectiveness. Volatile anesthetics are widely used for anesthesia maintenance during operations. Sevoflurane has more hemodynamic stability compared to isoflurane, but there are few studies comparing the hemodynamic stabilities of these two anesthetics during controlled low flow anesthesia with LMA. OBJECTIVES The aim of this study was to compare the effects of low-flow sevoflurane and low-flow isoflurane on hemodynamic parameters of patients through LMA. PATIENTS AND METHODS Eighty patients, scheduled for elective ophthalmic surgery, were randomly divided into two groups. After induction, an LMA with an appropriate size was inserted in all the patients and they were randomly allocated to two groups of low-flow sevoflurane (n = 40) and low-flow isoflurane (n = 40). Hemodynamic parameters (heart rate (HR), systolic blood pressure (SBP), diastolic blood pressure (DBP) and Mean Arterial Pressure (MAP) were recorded at 5, 10, 15, 20, 25 and 30 minutes after the anesthesia induction. RESULTS The mean heart rate values were significantly less in the sevoflurane group (P value < 0.05) at 25 minutes after the surgery. The mean Blood Pressure in the isoflurane group was significantly higher compared with the sevoflurane group in 10, 20 and 30 minutes after the surgery (P values = 0.0131, 0.0373 and 0.0028, respectively). These differences were clinically unimportant because heart rate and mean blood pressure were on normal ranges. CONCLUSIONS Seemingly, low-flow sevoflurane with LMA did not have any significant hemodynamic effect on clinical practice. Therefore, low-flow sevoflurane anesthesia with LMA might be considered in patients with short operations who need rapid recovery from anesthesia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hemodynamic responses to insertion of the laryngeal mask airway versus Combitube

Introduction: One of the most common problems during laryngoscopy involves sympathetic system stimulation and the subsequent hemodynamic changes. It is a key measure to maintain the hemodynamic stability of patients with cardiovascular diseases during induction of anesthesia. This study attempted to compare the hemodynamic effects of laryngeal mask airway and combitube. Methods: This prospec...

متن کامل

Comparison of postoperative complication between Laryngeal Mask Airway and endotracheal tube during low-flow anesthesia with controlled ventilation

OBJECTIVE To compare the postoperative complications between Laryngeal Mask Airway (LMA) and endotracheal tube (ETT) during low-flow anesthesia with controlled ventilation. METHODOLOGY Eighty adult Patients with ASA class I or II were randomly allocated into two forty-patient groups (ETT or LMA). Cuff pressure was monitored during anesthesia. After high uptake period, fresh gas flow (FGF) was...

متن کامل

Effects of proseal laryngeal mask airway cuff inflation on caro- tid flow in pediatric population during sevoflurane induction

Introduction The study examined the effects of cuff inflation of a ProSeal Laryngeal Mask Airway on the carotid bulb during sevoflurane induction in pediatric population. The hemodynamic parameters measured were: systolic and diastolic pressure, heart rate and sovraortic flow trough measurements of bilateral carotid cross sectional area, velocity of blood flow, resistance index, flow accelerati...

متن کامل

Pressure controlled versus volume controlled ventilation with laryngeal mask airway.

STUDY OBJECTIVE To quantify the impact on peak airway pressure of pressure-controlled and volume-controlled ventilation during Laryngeal Mask Airway (LMA) use. DESIGN Prospective, crossover clinical study. SETTING University-affiliated hospital. PATIENTS 32 ASA physical status I and II patients undergoing general anesthesia with the LMA. INTERVENTIONS Patients were ventilated for three ...

متن کامل

Comparison of the Incidence of Sore Throat and Hemodynamic Changes in ‎Airway Management by Macintosh, Glideoscope Laryngoscope and ‎Laryngeal Mask Airway Techniques: Randomized Controlled Trial

Background: Studies have shown that postoperative sore throat is the most common complication of tracheal intubation, However, the actual incidence and extent of it are not well documented. Objective: The aim of this study was to evaluate and compare the incidence of sore throat and hemodynamic Changes in Macintosh, Glidescope Laryngoscope and laryngeal mask airway  techniques in elective surg...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2014