Development of a hip joint model for finite volume simulations.

نویسندگان

  • P Cardiff
  • A Karač
  • D FitzPatrick
  • A Ivanković
چکیده

This paper establishes a procedure for numerical analysis of a hip joint using the finite volume method. Patient-specific hip joint geometry is segmented directly from computed tomography and magnetic resonance imaging datasets and the resulting bone surfaces are processed into a form suitable for volume meshing. A high resolution continuum tetrahedral mesh has been generated, where a sandwich model approach is adopted; the bones are represented as a stiffer cortical shells surrounding more flexible cancellous cores. Cartilage is included as a uniform thickness extruded layer and the effect of layer thickness is investigated. To realistically position the bones, gait analysis has been performed giving the 3D positions of the bones for the full gait cycle. Three phases of the gait cycle are examined using a finite volume based custom structural contact solver implemented in open-source software OpenFOAM.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Finite Element Analysis of Different Hip Implant Designs along with Femur under Static Loading Conditions

Background: The hip joint is the largest joint after the knee, which gives stability to the whole human structure. The hip joint consists of a femoral head which articulates with the acetabulum. Due to age and wear between the joints, these joints need to be replaced with implants which can function just as a natural joint. Since the early 19th century, the hip joint arthroplasty has evolved, a...

متن کامل

Biomechanics for preoperative planning and surgical simulations in orthopaedics.

Surgical simulations are particularly appropriate for the large volume and expense of joint replacement procedures in orthopaedics. A first generation surgical simulator has been developed to model the implantation procedure for cementless acetabular and femoral components in total hip replacement surgery. The simulator is based upon finite element analysis and predicts the early postoperative ...

متن کامل

4D geomechanical simulations for field development planning

3D and 4D geomechanical can be time-consuming to build and calibrate. However, once such a model is built, it is relative straightforward to use this model for various field development and management applications. In so doing, the return on the initial investment of time and effort in the creation of a 4D geomechanical model can be substantial. I present a case study where a 4D geomechanical m...

متن کامل

Muscle moment and angle of hip, knee and ankle joints in a seven- link model of backpack sprayer operator

Background and Aim: Carriage of backpack sprayers is an inevitable part of agricultural operations that increases the risk of injury along with undesirable changes in walking mechanics. The purpose of this study is to formulate the muscle moment changes in the hip, knee and ankle for the backpack sprayer operator body. Methods: In this study, a seven-link sprayer operator model is designed and...

متن کامل

Crash Injury Analysis of Knee Joint Considering Pedestrian Safety

Background: Lower extremity injuries are frequently observed in car-to-pedestrian accidents and due to the bumper height of most cars, knee joint is one of the most damaged body parts in car-to-pedestrian collisions.Objective: The aim of this paper is first to provide an accurate Finite Element model of the knee joint and second to investigate lower limb impact biomechanics in car-to-pede...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of biomechanical engineering

دوره 136 1  شماره 

صفحات  -

تاریخ انتشار 2014