Pain and stress assessment after retinopathy of prematurity screening examination: Indirect ophthalmoscopy versus digital retinal imaging

نویسندگان

  • M Teresa Moral-Pumarega
  • Sonia Caserío-Carbonero
  • Javier De-La-Cruz-Bértolo
  • Pilar Tejada-Palacios
  • David Lora-Pablos
  • Carmen R Pallás-Alonso
چکیده

BACKGROUND Increasingly, neonatal clinics seek to minimize painful experiences and stress for premature infants. Fundoscopy performed with a binocular indirect ophthalmoscope is the reference examination technique for screening of retinopathy of prematurity (ROP), and it is associated with pain and stress. Wide-field digital retinal imaging is a recent technique that should be evaluated for minimizing infant pain and stress. METHODS The purpose of the study was to assess and compare the impact of using a binocular indirect ophthalmoscope (BIO), or wide-field digital retinal imaging (WFDRI) on pain and stress in infants undergoing ROP screening examination. This was a comparative evaluation study of two screening procedures. Ophthalmologic examinations (N = 70) were performed on 24 infants with both BIO and WFDRI. Pain assessments were performed with two specific neonatal scales (Crying, requires oxygen, increased vital signs, expression and sleeplessness, CRIES and, Premature infant pain profile, PIPP) just prior to the examination, and 30 seconds, 1 hour, and 24 hours later after ending the examination. RESULTS Changes over time were significantly different between BIO and WFDRI with both scales (PIPP score, p = .007, and CRIES score, p = .001). Median PIPP score (interquartile interval) at baseline was 4 (3-5). At 30 seconds the score was 8 (6-9) for BIO and 6 (5-7) for WFDRI, respectively. The increase in PIPP score between baseline and 30 seconds was significantly lower with WFDRI (p = .006). The median increase in CRIES score from baseline to 30 seconds was 1 point lower for WFDRI than for BIO (p < .001). No significant difference in response remained at 1 hour or 24 hour assessments. CONCLUSIONS A transient short-term pain and stress response occurs with both BIO and WFDRI. Infants examined for screening of ROP with digital retinal imaging present less pain and stress at 30 seconds following completion of the exam when compared with binocular indirect ophthalmoscopy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficacy of wide-field digital retinal imaging for retinopathy of prematurity screening.

BACKGROUND To evaluate the efficacy of wide-field digital retinal imaging for retinopathy of prematurity screening. DESIGN Retrospective study in a quaternary public neonatal intensive care unit. PARTICIPANTS A total of 108 premature infants screened for retinopathy of prematurity. METHODS Retrospective chart and photo review were performed on participants screened by both serial wide-fie...

متن کامل

Screening and treatments using telemedicine in retinopathy of prematurity

Several studies have validated the role of telemedicine as a new powerful screening and diagnostic tool for retinal disorders, such as diabetic retinopathy and retinopathy of prematurity. With regard to retinopathy of prematurity, bedside examination with binocular indirect ophthalmoscopy has been the gold standard technique for screening, yet with several limitations. Herein, we review the cur...

متن کامل

Wide-field digital retinal imaging for retinopathy of prematurity screening in Australasia: a survey of practicing ophthalmologists.

PURPOSE To compare retinopathy of prematurity (ROP) screening experiences using binocular indirect ophthalmoscopy (BIO) and wide-field digital retinal imaging (WFDRI) at centers in Auckland, New Zealand, with those of other centers in Australasia. METHODS A web-based survey regarding methods of screening for ROP was distributed to ophthalmologists in Australia and New Zealand. RESULTS Thirt...

متن کامل

Retinal imaging in premature infants using the Pictor noncontact digital camera.

PURPOSE To evaluate, first, the feasibility of using Pictor, a new portable, noncontact digital fundus camera, to obtain high-quality retinal images of prematurely born infants and, second, the accuracy of grading these images for clinically significant posterior pole vascular changes, that is, pre-plus or plus disease, compared to indirect ophthalmoscopy. METHODS Pictor retinal images were o...

متن کامل

[Reliability of retinal imaging screening in retinopathy of prematurity].

INTRODUCTION The retinopathy of prematurity (ROP) is a potentially avoidable cause of blindness in children. The advances in neonatal care make the survival of extremely premature infants, who show a greater incidence of the disease, possible. The aim of the study is to evaluate the reliability of ROP screening using retinography imaging with the RetCam 3 wide-angle camera and also study the va...