Reliability in multi-site structural MRI studies: effects of gradient non-linearity correction on phantom and human data.

نویسندگان

  • Jorge Jovicich
  • Silvester Czanner
  • Douglas Greve
  • Elizabeth Haley
  • Andre van der Kouwe
  • Randy Gollub
  • David Kennedy
  • Franz Schmitt
  • Gregory Brown
  • James Macfall
  • Bruce Fischl
  • Anders Dale
چکیده

Longitudinal and multi-site clinical studies create the imperative to characterize and correct technological sources of variance that limit image reproducibility in high-resolution structural MRI studies, thus facilitating precise, quantitative, platform-independent, multi-site evaluation. In this work, we investigated the effects that imaging gradient non-linearity have on reproducibility of multi-site human MRI. We applied an image distortion correction method based on spherical harmonics description of the gradients and verified the accuracy of the method using phantom data. The correction method was then applied to the brain image data from a group of subjects scanned twice at multiple sites having different 1.5 T platforms. Within-site and across-site variability of the image data was assessed by evaluating voxel-based image intensity reproducibility. The image intensity reproducibility of the human brain data was significantly improved with distortion correction, suggesting that this method may offer improved reproducibility in morphometry studies. We provide the source code for the gradient distortion algorithm together with the phantom data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

اندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی

Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...

متن کامل

MRI-derived measurements of human subcortical, ventricular and intracranial brain volumes: Reliability effects of scan sessions, acquisition sequences, data analyses, scanner upgrade, scanner vendors and field strengths

Automated MRI-derived measurements of in-vivo human brain volumes provide novel insights into normal and abnormal neuroanatomy, but little is known about measurement reliability. Here we assess the impact of image acquisition variables (scan session, MRI sequence, scanner upgrade, vendor and field strengths), FreeSurfer segmentation pre-processing variables (image averaging, B1 field inhomogene...

متن کامل

Computational Algorithm for Estimating the Gradient Isocenter of an MRI Scanner

The isocenter of the magnetic gradient fields inside a magnetic resonance imaging scanner is an important parameter in gradient non-linearity distortion correction methods for MR images. Currently there is no established method for estimating the gradient isocenter. All existing correction methods assume that the gradient isocenter coincides with the DICOM coordinate center, which is close but ...

متن کامل

Brain morphometry reproducibility in multi-center 3 T MRI studies: A comparison of cross-sectional and longitudinal segmentations

Large-scale longitudinal multi-site MRI brain morphometry studies are becoming increasingly crucial to characterize both normal and clinical population groups using fully automated segmentation tools. The test-retest reproducibility of morphometry data acquired across multiple scanning sessions, and for different MR vendors, is an important reliability indicator since it defines the sensitivity...

متن کامل

Phantom Design for Distortion Correction of MR Images

AGNETIC resonance imaging (MRI) provides an excellent modality for distinguishing different tissues in the human body, which is essential for medical applications. When MRI is used for stereotactic treatment planning, its geometric accuracy is crucial. Previous studies have been conducted to correct the distortion caused by nonlinearity of the MRI scanner’s magnetic gradient fields by imaging a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • NeuroImage

دوره 30 2  شماره 

صفحات  -

تاریخ انتشار 2006