Determination of 17 β-Estradiol in Rabbit Plasma by Gas Chromatography with Flame Ionization Detection
نویسندگان
چکیده
This article describes gas chromatography-flame ionization detection method for determination of 17 β-estradiol in rabbit plasma. 17 β-estradiol and internal standard progesterone were extracted from plasma using liquid-liquid extraction method. Linearity was found between 0.25 and 20 μg/ml (r(2)=0.994) for plasma samples. Intra-day and inter-day precision, expressed as the relative standard deviation were less than 5.5%, and accuracy (relative error) was less than 3.5%. The mean recovery of 17 β-estradiol samples was 94.4%. The limits of detection and quantification of method for plasma samples were 0.10 μg/ml and 0.15 μg/ml, respectively. Also, clinically used other 10 drugs were investigated to check for potential interferences and the method was successfully applied to the determination of 17 β-estradiol in New Zealand white rabbits.
منابع مشابه
Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection
Objective(s): Dispersive liquid-liquid microextraction coupled with gas chromatography (GC)-flame ionization detector was developed for the determination of valproic acid (VPA) in human plasma. Materials and Methods: Using a syringe, a mixture of suitable extraction solvent (40 µl chloroform) and disperser (1 ml acetone) was quickly added to 10 ml of diluted plasma sample containing VPA (pH, 1....
متن کاملDetermination of Synthetic Phenolic Antioxidants in Biological Fluids Based on Air-assisted Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection
An air–assisted liquid–liquid microextraction method for the extraction and preconcentration of trace amounts of some synthetic phenolic antioxidants in biological fluids followed by their determination by gas chromatography–flame ionization detection has been reported. In this method the target analytes are extracted into a few microliters of carbon tetrachloride (extraction solvent) from an a...
متن کاملDetermination of 2-phenylethanol in Rose Water Using Dispersive Liquid-Liquid Microextraction with Gas Chromatography Flame Ionization Detection
A simple and rapid microextraction procedure based on dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-flame ionization detection (GC-FID) was developed for the extraction and analysis of 2-phenylethanol in rose water sample. In the proposed approach, carbon tetrachloride and ethanol were used as extraction and dispersive solvents, respectively. Some important pa...
متن کاملDetermination of Two Antiepileptic Drugs in Urine by Homogenous Liquid-Liquid Extraction Performed in A Narrow Tube Combined With Dispersive Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection
A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...
متن کاملDetermination of Two Antiepileptic Drugs in Urine by Homogenous Liquid-Liquid Extraction Performed in A Narrow Tube Combined With Dispersive Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection
A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...
متن کامل