Acoustic and thermal characterization of agar based phantoms used for evaluating focused ultrasound exposures

نویسندگان

  • Georgios Menikou
  • Christakis Damianou
چکیده

BACKGROUND This study describes a series of experimental work completed towards characterizing candidate materials for fabricating brain and muscle tissue mimicking phantoms. METHODS The acoustic speed, attenuation, impedance, thermal diffusivity, specific heat and thermal conductivity were measured. RESULTS The resulting brain (2% w/v agar-1.2% w/v Silica Dioxide-25%v/v evaporated milk) and muscle tissue recipe (2% w/v agar-2% w/v Silica Dioxide-40%v/v evaporated milk) introduced a total attenuation coefficient of 0.59 dB/cm-MHz and 0.99 dB/cm-MHz respectively. Acrylonitrile Butadiene Styrene (ABS) possessed an attenuation coefficient of 16 dB/cm at 1 MHz which was found within the very wide range of attenuation coefficient values of human bones in literature. The thermal conductivity of the brain tissue phantom was estimated at 0.52 W/m°C and at 0.57 W/m.°Cfor the muscle. These values demonstrated that the proposed recipes conducted heat similar to the majority of most soft tissues found from bibliography. The soft tissue phantoms were also evaluated for their thermal repeatability after treating them repeatedly at different locations with the same sonication protocol and configuration. The average coefficient of variation of the maximum temperature at focus between the different locations was 2.6% for the brain phantom and 2.8% for the muscle phantom. CONCLUSIONS The proposed phantom closely matched the acoustic and thermal properties of tissues. Experiments using MR thermometry demonstrated the usefulness of this phantom to evaluate ultrasonic exposures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gold nanoparticle nucleated cavitation for enhanced high intensity focused ultrasound therapy.

High intensity focused ultrasound (HIFU) or focused ultrasound surgery is a non-invasive technique for the treatment of cancerous tissue, which is limited by difficulties in getting real-time feedback on treatment progress and long treatment durations. The formation and activity of acoustic cavitation, specifically inertial cavitation, during HIFU exposures has been demonstrated to enhance heat...

متن کامل

Numerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator

Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...

متن کامل

Time-course Characterization of High-intensity Focused Ultrasound Exposure Using B-mode Ultrasound Imaging

High-Intensity Focused Ultrasound (HIFU) is an emerging non-invasive surgical technique. HIFU systems are generally designed to deliver a fixed amount of energy to tissue, but because the tissue thermal response is variable across patients and tissue type, this approach can often lead to underdosing or overdosing. In order to improve the dosing precision in HIFU we are investigating real time m...

متن کامل

Harmonic Motion Imaging (HMI) for Tumor Imaging and Treatment Monitoring.

Palpation is an established screening procedure for the detection of several superficial cancers including breast, thyroid, prostate, and liver tumors through both self and clinical examinations. This is because solid masses typically have distinct stiffnesses compared to the surrounding normal tissue. In this paper, the application of Harmonic Motion Imaging (HMI) for tumor detection based on ...

متن کامل

Blood Brain Barrier Disruption by Focused Ultrasound and Microbubbles: A Numerical Study on Mechanical Effects

Introduction: Microbubbles are widely used as contrast agent in diagnostic ultrasound. Recently they have shown good potential for applications in the therapeutic field such as drug delivery to the brain. Recent studies have shown focused ultrasound in conjunction with injected micro-bubbles could temporarily disrupt blood-brain barrier and let therapeutic agents transport into...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2017