Vascular Perforation During Coil Embolization of an Intracranial Aneurysm: the Incidence, Mechanism, and Clinical Outcome
نویسندگان
چکیده
PURPOSE The occurrence of a vascular perforation during an endovascular procedure is an unexpected and feared complication which can be fatal. However, the incidence, risk or the mechanism of vascular perforation which can occur in the endovascular management of aneurysms remains unclear. The purpose of the present study was to evaluate the incidence of vascular perforation during endovascular coil embolization of a cerebral aneurysm, and to reveal characteristics and clinical outcomes. MATERIALS AND METHODS We reviewed the endovascular coil embolization procedures performed for the treatment of 459 aneurysms. Incidence and clinical, radiological and technical data of patients concerning the vascular perforation were reviewed from medical records and radiological findings. RESULTS The incidence of procedure-related vascular perforation in our patient group was 0.87% (4/459). For all four occurrences, the cause of vascular perforation involved the guidewire or microcatheter. Clinical outcome was poor in 2 cases and favorable in 2 cases. CONCLUSION Although rare, the occurrence of vascular perforation during coil embolization for treatment of an aneurysm may be fatal. Therefore, careful management of the guidewire is suggested for the prevention of vascular rupture during an endovascular procedure.
منابع مشابه
Rebleeding of Ruptured Intracranial Aneurysms in the Immediate Postoperative Period after Coil Embolization
OBJECTIVE Early rebleeding after coil embolization of ruptured intracranial aneurysms is rare, however serious and fatal results of rebleeding have been reported. We studied the incidence and angiographic and clinical characteristics of rebleeding of ruptured aneurysms occurring in the immediate postoperative period after coil embolization. MATERIALS AND METHODS We analyzed patients who had a...
متن کاملSurgical salvage of microcatheter-induced aneurysm perforation during coil embolization.
We report a case of iatrogenic aneurysm rupture during coil embolization in a 55-year-old woman. Surgical intervention resulted in a good clinical outcome. To our knowledge, this technique for the salvage of catheter-induced aneurysm perforation has not been previously reported.
متن کاملRupture of intracranial aneurysms during endovascular coiling: management and outcomes.
OBJECTIVE In this study, the incidence, etiologies, and management with respect to clinical outcome of patients with iatrogenic aneurysmal rupture during attempted coil embolization of intracranial aneurysms are reviewed. METHODS A retrospective analysis was conducted of 274 patients with intracranial aneurysms treated with Guglielmi detachable coils over a 6-year period from 1994 to 2000. Pa...
متن کاملIntraprocedure aneurysm rupture in embolization: clinical outcome with imaging correlation.
BACKGROUND Intraprocedural aneurysm rupture (IPAR) is the most feared complication of embolization for intracranial aneurysms. Here we report the immediate and long-term imaging outcomes of IPAR during embolization and the correlation with clinical outcomes. METHODS Of the 376 consecutive patients harboring 412 intracranial aneurysms who had underwent endovascular coil embolizations in the pa...
متن کاملIntraprocedural aneurysmal rupture during coil embolization of brain aneurysms: role of balloon-assisted coiling.
BACKGROUND AND PURPOSE Intraprocedural aneurysmal rupture is a feared complication of coil embolization of intracranial aneurysms and is associated with high rates of morbidity and mortality. We report the incidence, endovascular management, and clinical outcome of patients with IAR, with emphasis on the role of the balloon-assisted technique. MATERIALS AND METHODS We conducted a retrospectiv...