A Completely Intramedullary Leg Lengthening Device

نویسندگان

  • A. M. M. Aalsma
  • E. E. G. Hekman
  • J. Stapert
  • H. Grootenboer
چکیده

The procedure and the external fixator for lengthening long bones was developed by G. A. Ilizarov in the late 1960's. This technique has, despite its proven abilities for leg lengthening and correction of angular deformities, some considerable disadvantages for the patients. Discomfort, infections and restricted weight bearing are some reasons for the development of a completely intramedullary device for leg lengthening. The device developed at the Laboratory of Biomechanical Engineering, University of Twente, is a telescopic intramedullary nail with a maximum diameter of 13 mm, which can be lengthened with 0.5 mm steps induced by a Shape Memory Alloy Actuator. The electrical energy for the actuator is supplied from outside the body by inductive coupling of two solenoid coils. Internaly, the electrical energy is transformed to thermal energy by Thermofoils and Peltierelements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intramedullary leg lengthening with a motorized nail

BACKGROUND AND PURPOSE In the last decade, intramedullary limb lengthening has become a viable alternative to traditional external systems. We retrospectively analyzed the use of an intramedullary motorized nail (Fitbone) in a consecutive series of 32 patients. PATIENTS AND METHODS During the period September 2006 to December 2008, 32 consecutive patients with a median age of 17 (IQR: 15-19) ...

متن کامل

Lengthening of the femur over an existing intramedullary nail.

Leg length discrepancies can occur despite successful union of femur fractures after intramedullary nailing (IMN). Often, the leg length discrepancy can result in significant disability to the patient, altered gait biomechanics, pelvic obliquity, and pain. Therefore, a successful clinical result for such deformities after IMN involves addressing the leg length inequality. Femoral reconstruction...

متن کامل

TECHNICAL TRICK Lengthening of the Femur Over an Existing Intramedullary Nail

Leg length discrepancies can occur despite successful union of femur fractures after intramedullary nailing (IMN). Often, the leg length discrepancy can result in significant disability to the patient, altered gait biomechanics, pelvic obliquity, and pain. Therefore, a successful clinical result for such deformities after IMN involves addressing the leg length inequality. Femoral reconstruction...

متن کامل

Femoral lengthening with a motorized intramedullary nail

PURPOSE We assessed whether an intramedullary lengthening device would reduce the problems normally associated with the external fixation technique. We also wanted to determine whether it is a reliable construct for limb lengthening and deformity correction in the femur. PATIENTS AND METHODS We conducted a matched-pair comparison of 30 femoral lengthenings, 15 with a motorized intramedullary ...

متن کامل

Intramedullary limb lengthening with the Intramedullary Skeletal Kinetic Distractor in the lower limb.

We report the results of intramedullary leg lengthening conducted between 2002 and 2009 using the Intramedullary Skeletal Kinetic Distractor in 69 unilateral lengthenings involving 58 femora and 11 tibiae. We identified difficulties that occurred during the treatment and assessed whether they were specifically due to the implant or independent of it. Paley's classification for evaluating proble...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004