This study used finite element (FE) analysis with the load-controlled method (LCM) and the displacement-controlled method (DCM) to examine motion differences at the implant level and adjacent levels between fusion and non-fusion implants. A validated three-dimensional intact (INT) L1-L5 FE model was used. At the L3-L4 level, the INT model was modified to surgery models, including the artificial disc replacement (ADR) of ProDisc II, and the anterior lumbar interbody fusion (ALIF) cage with pedicle screw fixation. The LCM imposed 10 Nm moments of four physiological motions and a 150 N preload at the top of L1. The DCM process was in accordance with the hybrid testing protocol. The average percentage changes in the range of motion (ROM) for whole non-operated levels were used to predict adjacent level effects (ALE%). At the implant level, the ALIF model showed similar stability with both control methods. The ADR model using the LCM had a higher ROM than the model using the DCM, especially in extension and torsion. At the adjacent levels, the ALIF model increased ALE% (at least 17 per cent) using the DCM compared with the LCM. The ADR model had an ALE% close to that of the INT model, using the LCM (average within 6 per cent), while the ALE% decreased when using the DCM. The study suggests that both control methods can be adopted to predict the fusion model at the implant level, and similar stabilization characteristics can be found. The LCM will emphasize the effects of the non-fusion implants. The DCM was more clinically relevant in evaluating the fusion model at the adjacent levels. In conclusion, both the LCM and the DCM should be considered in numerical simulations to obtain more realistic data in spinal implant biomechanics.
منابع مشابه
Comparison of the Load and Displacement Controlled Finite Element Analyses on Fusion and Non-fusion Spinal Implants
INTRODUCTION In recent year, the design concepts of spinal implants alternation from traditional stable fusion to restore normal spinal range of motion (ROM). Therefore, the method of the spinal implants in vitro test was advanced from traditional load control method (LCM) to displacement control method (DCM) [1-3]. In real life, it is still not clear whether to use LCM or the DCM to evaluate t...
متن کاملExperimental Evaluations of Intervertebral Disc Mechanics Following Posterolateral Fusion are Dependent on Testing Protocol
IntroductionNumerous studies have sought to quantify the biomechanical effects of posterior spinal fusion and disc arthroplasty; however, the results from these studies are conflicting. Additionally, the variety of techniques utilized during biomechanical testing complicates comparing results of instrumentation studies. Two distinct methods of experimental loading protocols have emerged to test...
متن کاملAssessment of the suitability of biodegradable rods for use in posterior lumbar fusion: An in-vitro biomechanical evaluation and finite element analysis
Interbody fusion with posterior instrumentation is a common method for treating lumbar degenerative disc diseases. However, the high rigidity of the fusion construct may produce abnormal stresses at the adjacent segment and lead to adjacent segment degeneration (ASD). As such, biodegradable implants are becoming more popular for use in orthopaedic surgery. These implants offer sufficient stabil...
متن کاملAnalysis of the Biomechanical Characteristics of the Spinal Interspinous Implants
Spinal decompression surgery with spinal fusion is a widely used surgical procedure for the treatment of degenerative spine in the lumbar spine. However, it has been known that spinal decompression surgery causes the spinal instability. Some cadaveric and finite element (FE) studies have reported that adjacent segment degeneration may reduce adverse effects on the adjacent levels resulting from...
متن کاملFinite Element Studies on Friction Stir Welding Processes of Polyethylene Plates
One of the interesting state-of-the-art approaches to welding is the process of friction stir welding (FSW). In comparison with the fusion processes, FSW is an advantageous method as it is suitable for the non-fusion weldable alloys and polymeric materials joining. Regarding the materials pure solid state joining, it also provides joints with less distortion and enhanced mechanical properties. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine
دوره 223 2 شماره
صفحات -
تاریخ انتشار 2009