Shaping Ability of the Fifth Generation Ni-Ti Rotary Systems for Root Canal Preparation in Curved Root Canals using Cone-Beam Computed Tomographic: An In Vitro Study

نویسندگان

  • Deepak Jain
  • Ashish Medha
  • Neelam Patil
  • Nilam Kadam
  • Vandana Yadav
  • Harshal Jagadale
چکیده

Contributors: 1Reader, Department of Conservative Dentistry and Endodontics, SDS, Karad, Maharashtra, India; 2Professor and Head, Department of Conservative Dentistry and Endodontics, SDS, Karad, Maharashtra, India; 3Post-graduate Student, Department of Conservative Dentistry and Endodontics, SDS, Karad, Maharashtra, India Correspondence: Dr. Jain D. Department of Conservative Dentistry and Endodontics, School of Dental Sciences, Karad, Maharashtra, India. 803 Green Blaze Society, Juhu Versova Link Road, Andheri West, Mumbai 400 058, Maharashtra, India. Phone: +91-9820514093. Email: [email protected] How to cite the article: Jain D, Medha M, Patil N, Kadam N, Yadav V, Jagadale H. Shaping ability of fi fth generation Ni-Ti rotary systems for root canal preparation in curved root canals using cone-beam computed tomographic: An in vitro study. J Int Oral Health 2015;7 (Suppl 1):57-61. Abstract: Background: Various root canal systems are available commercially with each manufacturer stating superior characteristics of their respective systems. The fi fth generation root canal systems claim to have better fl exibility and superior debris elimination due to their off set design. This study aims to compare the eff ects of fi fth generation rotary systems on canal curvature, transportation and centering ratio of curved mesial root canals of mandibular molar via cone-beam computed tomographic (CBCT) imaging. Materials and Methods: With curvature ranging from 20° to 40°, 60 mandibular fi rst molars with mesiobuccal root angle were divided into three groups with 20 canals each. Before instrumentation, the groups were balanced with respect to the angle of canal curvature based on CBCT images taken. All root canals were shaped to an apical size of 25: OneShape (OS) (Micro Mega, Besancon, France), ProTaper Next (PTN) (Dentsply Maillefer), Revo S (RS) (Micro Mega, Besancon, France). CBCT assessment was done post instrumentation. SPSS version 16 software was used for statistical analysis. The signifi cance level was set at P = 0.05. Results: The RS system maintained better canal centricity and less transportation as compared to PTN and OS. There was no signifi cant diff erence among the three groups in canal curvature after instrumentation. Conclusions: All fi le systems used straightened the root canal curvature similarly. RS instrumentation exhibited superior performance compared with the OS and PTN systems with respect to transportation and centering ratio.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Canal Transportation and Centering Ability of Wave One and SafeSider in Curved Root Canals Using Cone-Beam Computed Tomography

Background and Aim: Maintaining the original central canal path during cleaning and shaping of the root canal system plays an important role in the success of endodontic treatment. This study sought to compare canal transportation and centering ability of WaveOne and SafeSider rotary files using cone-beam computed tomography (CBCT). Materials and Methods: This in-vitro, experimental study was ...

متن کامل

Comparison of transportation and centering ability using RECIPROC and iRace: A cone-beam computed tomography study

BACKGROUND AND AIM: Root canal treatment, especially in curved and constricted root canals, can be very difficult and time consuming. Several investigations have compared the reciprocating and full sequence motions in terms of shaping ability. The purpose of the present study was to compare the root canal transportation and centering ability of RECIPROC and iRace using cone-beam computed tomogr...

متن کامل

مقایسه ترانسپورتیشن دو سیستم روتاری رسیپروک و نئولیکس در کانال‌های انحنادار ریشه دندان توسط توموگرافی کامپیوتری با اشعه مخروطی

Background and Objective: The preparation of the root canal (i.e., cleaning and shaping) is the main step in the endodontic treatment. The nickel-titanium rotary files result in fewer errors during the preparation of curved canals. This study aimed to compare the transportation of Neolix and Reciproc rotary systems in curved canals using cone beam computed tomography (CBCT). Materials and Meth...

متن کامل

Shaping Ability of NiTi Rotary versus Stainless-Steel Hand Instruments in Curved Root Canals of Extracted Teeth

Introduction: The purpose of this in-vitro study was to compare shaping ability of NiTi rotary Mtwo and FlexMaster with stainless steel hand K-Flexofile in curved root canals of extracted teeth. Materials and Methods: Mesiobuccal canals of 45 mandibular molar teeth were balanced into three groups of 15 each, with respect to the Schneider angle, canal access angle, height, dis-tance and radiu...

متن کامل

Reciprocating vs Rotary Instrumentation in Pediatric Endodontics: Cone Beam Computed Tomographic Analysis of Deciduous Root Canals using Two Single-file Systems

BACKGROUND Primary root canals are considered to be most challenging due to their complex anatomy. "Wave one" and "one shape" are single-file systems with reciprocating and rotary motion respectively. The aim of this study was to evaluate and compare dentin thickness, centering ability, canal transportation, and instrumentation time of wave one and one shape files in primary root canals using a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2015