Real-time point of care microcirculatory assessment of shock: design, rationale and application of the point of care microcirculation (POEM) tool
نویسندگان
چکیده
BACKGROUND Despite over a decade of research and technological advances, sublingual microcirculatory monitoring has not yet reached clinical utility. Offline analysis is time consuming and occurs away from the patient. A system to assess the microcirculation at the point of care is desirable. We present a novel 5-point grading system (the point of care microcirculation (POEM) scoring system) that can be used at the point of care during non-invasive sublingual microcirculatory monitoring. METHODS The POEM score is an ordinal scale from 1 (worst) to 5 (best), based on a composite assessment of flow and heterogeneity of four individual sublingual video-microscopy clips. Thirty-two healthcare professionals were trained in how to assign POEM scores. Following training they assigned scores to five test sequences (each consisting of four video clips). They were blinded to clinical status. Inter-user consistency and agreement were assessed using intra-class correlation coefficient (ICC) analysis. In addition, blinded expert scores for 68 video clips were compared to offline computer analysis using traditional microcirculatory parameters including total vessel density (TVD), perfused vessel density (PVD), proportion of perfused vessels (PPV), microcirculatory flow index (MFI) and microcirculatory heterogeneity index (MHI). The time taken to assign each was recorded. RESULTS Participants showed good inter-rater consistency (ICC 0.83, 95 % CI 0.626, 0.976) and agreement (ICC 0.815, 95 % CI 0.602, 0.974) for assigned POEM scores. Expert scoring of videos correlated with offline values for PVD (R 2 = 0.39; p < 0.05), PPV (R 2 = 0.71; p < 0.001), MFI (R 2 = 0.75; p < 0.001), and MHI (R 2 = 0.68; p < 0.001). POEM scores took less time to assign than conventional offline computer analysis (2 minutes versus 44 minutes). CONCLUSION We present for the first time a novel 5-point ordinal scale of microcirculatory flow and heterogeneity that can be used at the point of care. It has minimal inter-user variability amongst healthcare professionals after just 1 hour of training. POEM scores take a short time to assign, and correspond well to traditional offline computer-analyzed parameters.
منابع مشابه
Venous-to-arterial CO2 differences and the quest for bedside point-of-care monitoring to assess the microcirculation during shock.
The microcirculation is the anatomical location of perfusion and substrate exchange, and its functional impairment is of paramount importance during the state of shock. The difference in venous-to-arterial carbon dioxide partial pressures (Pv-aCO2) has recently been reported to correlate with microcirculatory dysfunction during early septic shock with greater fidelity than global hemodynamic pa...
متن کاملReal-Time Kinematic Network of Tehran, from Design to Application
Following the request of the Tehran municipality and in order to provide the spatial information required in their various projects, a real-time kinematic network has been designed for Tehran. Based on the existing measures such as the dilution of precision at the network point positions, two different designs have been proposed. A minimum number of six GNSS stations are used in both of the pro...
متن کاملStudy Design of the Microcirculatory Shock Occurrence in Acutely Ill Patients (microSOAP): an International Multicenter Observational Study of Sublingual Microcirculatory Alterations in Intensive Care Patients
Objective. Sublingual microcirculatory alterations are associated with an adverse prognosis in several critical illness subgroups. Up to now, single-center studies have reported on sublingual microcirculatory alterations in ICU patient subgroups, but an extensive evaluation of the prevalence of these alterations is lacking. We present the study design of an international multicenter observation...
متن کاملHemodynamic coherence and the rationale for monitoring the microcirculation.
This article presents a personal viewpoint of the shortcoming of conventional hemodynamic resuscitation procedures in achieving organ perfusion and tissue oxygenation following conditions of shock and cardiovascular compromise, and why it is important to monitor the microcirculation in such conditions. The article emphasizes that if resuscitation procedures are based on the correction of system...
متن کاملField effect transistor nanobiosensors: State-of-the-art and key challenges as point of care testing devices
The existing health care systems focus on treating diseases rather than preventing them. Patients are generally not tested unless physiological symptoms are appeared. When they do get tested, the results often take several days and can be inconclusive if the disease is at an early stage. In order to facilitate the diagnostics process and make tests more readily available for patients, the conce...
متن کامل