Comparison of serum free light chain and urine electrophoresis for the detection of the light chain component of monoclonal immunoglobulins in light chain and intact immunoglobulin multiple myeloma.
نویسندگان
چکیده
Response criteria for multiple myeloma are based upon changes in monoclonal protein levels quantified using serum and/or urine protein electrophoresis. The latter lacks sensitivity at low monoclonal protein levels and since 2001, the serum free light chain test has been available and its clinical utility proven, yet guidelines have not recommended it as a replacement for urine assessment. Herein we evaluated responses using serum free light chain measurements and serum and urine electrophoresis after 2 and 4 cycles of therapy and after stem cell transplantation in 25 light chain and 157 intact immunoglobulin myeloma patients enrolled in the IFM 2007-02 MM trial. All 25 light chain patients had measurable disease by serum free light chain and urine methods at presentation. By contrast 98 out of 157 intact immunoglobulin patients had measurable disease by serum free light chain compared to 55 out of 157 by urine electrophoresis. In all patients there was substantial agreement between predicate (serum/urine protein electrophoresis) and test (serum protein electrophoresis and serum free light chain) methods for response assessment (Weighted Kappa=0.83). Urine immunofixation became negative in 47% light chain and 43% intact immunoglobulin patients after 2 cycles of therapy. At this time the serum free light chain ratio normalised in only 11% and 27% patients, respectively. In summary we found good agreement between methods for response assessment, but the serum free light chain test provided greater sensitivity than urine electrophoresis for monitoring. To our knowledge this is the first report comparing both methods for response assignment based on the International Myeloma Working Group guidelines. (Clinical Trials Register.eu identifier: 2007-005204-40).
منابع مشابه
Serum Free Light-chain Assay for the Diagnosis, Management, and Prognosis of Multiple Myeloma
In recent decades, new serum biomarkers have been developed for routine laboratory practice, such as assaying serum free light chains and more recently, assaying immunoglobulin heavy and light chain isotypes (Hevylite). In this work, we highlight the interest of new biomarkers (Hevylite Test) in the management of monoclonal gammopathies because of the technical advantages it confers and the se...
متن کاملتعیین اپی توپ های ناپیوسته زنجیره سبک ایمونوگلوبولین انسان توسط ایمونولوژی محاسبه ای
Background: Immunoglobulins are a group of proteins that have important role in defense against microorganisms. Immunoglobulins consist of heavy and light chains. In human, immunoglobulin light chain comprises of two isotypes: Kappa (K) and lambda (λ) based on amino acid differences in carboxylic end of their constant region. Marked changes in the K to λ ratio can happen in monocl...
متن کاملSerum free light chain assays not total light chain assays are the standard of care to assess Monoclonal Gammopathies.
The diagnosis of Multiple Myeloma is a challenge to the physician due to the non-specific symptoms (anemia, bone pain and recurrent infections) that are commonplace in the elderly population. However, early diagnosis is associated with less severe disease, including fewer patients presenting with acute renal injury, pathological fractures and severe anemia. Since 2006, the serum free light chai...
متن کاملSerum free light chain measurements move to center stage.
For more than 150 years, the presence of Bence Jones protein [immunoglobulin free light chains (FLCs)] in the urine has been an important diagnostic marker for multiple myeloma. Indeed, it was the first cancer test, and 100 years before any others (1 ). Over the last few years, however, interest in FLCs has undergone a renaissance. Development of serum tests for free and free has opened the doo...
متن کاملDevelopment and characterization of polyclonal antibody against human kappa light chain in rabbit
Polyclonal antibodies against kappa light chain are used to diagnose diseases producing free light chain. The kappa and lambda light chains are products of immunoglobulin synthesis and released into the circulation in minor amounts such as serum, cerebrospinal fluid, urine and synovial fluid in normal condition. The purpose of this study was the production and purification of polyclonal immunog...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Haematologica
دوره 101 3 شماره
صفحات -
تاریخ انتشار 2016