Simultaneous determination of gold and copper by reversed-phase high-performance liquid chromatography using online column enrichment as their syn-phenyl-2-pyridylketoximate chelates.

نویسندگان

  • S Ichinoki
  • T Okutani
  • N Konakawa
  • T Nakano
  • Y Fujii
چکیده

Gold and copper ions react with syn-phenyl-2-pyridylketoxime (PPKO) at 40 degrees C to form neutral chelates. Metal-PPKO chelates subsequently become preconcentrated on a minicolumn packed with a divinylbenzene-methacrylate copolymer. By switching the valve, these chelates are separated on the silica-based phenyl column and detected with a photometric detector. These processes occur automatically except for chelation. The results of the chelation, preconcentration, and separation conditions studies are presented. Calibration curves for Au and Cu ions are linear from nanograms per milliliter (parts per billion) to micrograms per milliliter (parts per million) in the original solution. The precision for 0.5-ppm standards of Au and Cu is 2.1 and 0.9 relative standard deviation (%), respectively. The accuracy of the present method is verified for Au and Cu based on the analysis of a standard alloy of the National Institute of Standards and Technology (NIST). The limits of detection for Au and Cu are 16.7 and 0.6 ppb, respectively. The effects of foreign ions on the determination of Au and Cu are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous determination of four heavy metal ions in tobacco and tobacco additive by online enrichment followed by RP-HPLC and microwave digestion.

A new method for the simultaneous determination of tin, lead, cadmium, and mercury in tobacco and tobacco additive by reversed-phase high-performance liquid chromatography combined with microwave digestion and an online enrichment technique is developed. The tin, lead, cadmium, and mercury ions are precolumn derivatized with tetra-(4-dimethylaminophenyl)-porphyrin (T(4)-DMAPP) to form color che...

متن کامل

Simultaneous determination of heavy metals in drinking waters and wines by methods: Ion pair-reversed phase high performance liquid chromatography and capillary zone electrophoresis

Simultaneous determination of metal ions in drinking waters and wines using ion paired reversed phase high performance liquid chromatography (IP−RPHPLC) and capillary zone electrophoresis (CZE) have been investigated. Co(II), Cu(II), Ni(II), Fe(II) and V(V) are analyzed as their Nitro-PAPS chelates. Reversed flow injection (rFI) is used for in-line complexation prior to their separation by IP-R...

متن کامل

Separation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column

The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...

متن کامل

Determination of chemical and radiochemical purity of [14C] clozapine by high performance liquid chromatography and liquid scintillation [Persian]

Introduction: The mechanism of action and metabolism of clozapine, a complex drug used in psychopharmacology, is not completely understood. The effects of this compound in human body are related to some interactions with serotonin and dopamine neurotransmitter receptors. To further elucidate the mechanism of action and to support ongoing drug metabolism studies, [14C] clozapine with suita...

متن کامل

Separation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column

The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatographic science

دوره 39 10  شماره 

صفحات  -

تاریخ انتشار 2001