Characterization of Lead–Phytochelatin Complexes by Nano-Electrospray Ionization Mass Spectrometry

نویسندگان

  • Christian Scheidegger
  • Marc J.-F. Suter
  • Renata Behra
  • Laura Sigg
چکیده

The role of phytochelatins (PC(n), metal-binding oligopeptides with the general structure (γGlu-Cys)(n)-Gly (n = 2-11) in metal detoxification is assumed to be based on immobilization of metals, which prevents binding of metals to important biomolecules. Although induction of phytochelatin synthesis has often been observed in algae upon exposure to metals, direct evidence for binding of the inducing metal to phytochelatins is scarce. In this study, a nano-electrospray ionization mass spectrometry (nano-ESI-MS) method is developed for identification and characterization of Pb(II)-PC(n) and Zn(II)-PC(n) complexes. Complexes of Pb(II) with standard PC(n) (n = 2-4; 0.25 mM Pb(II) and 0.5 mM PC(n)) were examined by nano-ESI-MS with respect to their stoichiometry. Pb-PC(n) mass spectra indicated the presence of the [M + H](+) peak of PC(n) and complexes with various stoichiometries. Analysis of Pb-PC(2) allowed the identification of four different complexes observed at m/z 746.10, 952.06, 1285.24, and 1491.20, corresponding to [Pb-PC(2)](+), [Pb(2)-PC(2)](+), [Pb-(PC(2))(2)](+), and [Pb(2)-(PC(2))(2)](+). Their m/z indicated coordination of Pb(II) by PC(2) through the thiol groups of PC cysteine and possibly carboxylic groups. For each of the standard PC(3) and PC(4), two different complexes were observed, corresponding to Pb-PC(3), Pb(2)-PC(3), Pb-PC(4), and Pb(2)-PC(4). The measured isotopic patterns were for all complexes identical to the theoretical isotopic patterns. Addition of Zn(II) (0.125-5 mM) to previously formed Pb-PC(2) complexes showed the appearance of the [Zn-PC(2)](+) complexes at m/z 602.05 and the decrease of the [Pb-PC(2)](+) peak. These findings corroborate the postulated Pb-PC complexes from a previous study using size exclusion chromatography of PC extracted from algae, as well as the concurrent formation of Pb-, Zn-, and Cu-PC complexes in algae.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Study of the Complexation of Mercury(II) with Dicysteinyl Tetrapeptides by Electrospray Ionization Mass Spectrometry.

In this study we evaluated a method for the characterization of complexes, formed in different relative ratios of mercury(II) to dicysteinyl tetrapeptide, by electrospray ionization orbitrap mass spectrometry. This strategy is based on previous successful characterization of mercury-dicysteinyl complexes involving tripeptides by utilizing mass spectrometry among other techniques. Mercury(II) ch...

متن کامل

Molecular characterization of organic aerosols using nanospray-desorption/electrospray ionization-mass spectrometry.

Nanospray desorption electrospray ionization (nano-DESI) combined with high-resolution mass spectrometry (HR-MS) is a promising approach for the detailed, molecular-level chemical characterization of atmospheric organic aerosols (OA) collected in laboratory and field experiments. The nano-DESI technique possesses distinct advantages of technical simplicity, enhanced sensitivity, and signal stab...

متن کامل

Use of electrospray ionization mass spectrometry for the characterization of actinide complexes in solution

In order to understand the mechanisms involved in the extraction processes developed to separate minor actinides, the “ligand/metallic cation” complexes formed in the organic phases are characterized by electrospray ionization-mass-spectrometry (ESI-MS). This paper deals with the application of the ESI-MS technique to analyze americium complexes in organic solutions. Two extractant systems are ...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2012