The world's worst chemical industrial disaster, which occurred at Bhopal on 2-3 December, 1984, resulted in considerable respiratory morbidity in the exposed population. Therefore, a study was planned to evaluate the relationship between lower respiratory tract inflammation, lung function and severity of exposure. Sixty patients exposed to methyl isocyanate and presenting with respiratory symptoms were studied using bronchoalveolar lavage (BAL) 1-7 yrs after the accident. Pulmonary function tests included forced vital capacity (FVC) and forced expiratory volume in one second (FEV1). An index of severity of exposure was derived retrospectively on the basis of the acute symptoms in the victims themselves or the occurrence of death among their family members. Total lung inflammatory cells (p < 0.01) and absolute numbers of macrophages (p = 0.01) and lymphocytes (p < 0.05) increased as severity of exposure increased. FEV1/FVC % (p = 0.05) was also significantly lower as severity of exposure increased. Moderately exposed subjects had significantly lower FEV1/FVC % (p < 0.05) compared to those mildly exposed. In nonsmokers, BAL neutrophils, both percentage and absolute numbers, showed significant negative correlations with FEV1 % predicted (rs = -0.350, p < 0.05; and rs = -0.374, p < 0.01, respectively). Neutrophil percentage was negatively correlated with FEV1/FVC % (rs = -0.378; p < 0.01). Absolute lymphocytes had significant negative correlations with FVC % pred (rs = -0.318; p < 0.05). Macrophages had significant positive correlations with FVC % pred (rs = 0.322; p < 0.05) and FEV1 % pred (rs = 0.433; p < 0.01). Radiographic abnormalities (International Labour Organization (ILO) classification) were associated with decline in FEV1 % pred (p < 0.05). This study suggests that pulmonary function abnormalities occur in gas-exposed subjects as a consequence of an abnormal accumulation of lung inflammatory cells (lymphocytes and neutrophils), and that the intensity of lung inflammation and reduction in pulmonary function are greater in severely exposed subjects. As it has been observed that decline in pulmonary function is associated with radiographic abnormalities, there is a suggestion that injury following toxic gas exposure can lead to irreversible lung damage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship between Lung Function and Flour Dust in Flour Factory Workers

Introduction: Exposure to flour dust is an important risk factor in occurrence of allergic airway disorders among mill workers. The purpose of this study was to determine the prevalence of respiratory symptoms and its relation with exposure to respirable dust. Materials and Methods: In this study, all of 35 workers who worked in the flour producing section of three factories were chosen as ca...

متن کامل

Time course changes of oxidative stress and inflammation in hyperoxia-induced acute lung injury in rats

Objective(s):Therapies with high levels of oxygen are commonly used in the management of critical care. However, prolonged exposure to hyperoxia can cause acute lung injury. Although oxidative stress and inflammation are purported to play an important role in the pathogenesis of acute lung injury, the exact mechanisms are still less known in the hyperoxic acute lung injury (HALI).   Materials ...

متن کامل

RELATIONSHIP BETWEEN CONCENTRATION OF WELDING FUMES AND CHANGES IN WELDERS\' LUNG FUNCTIONS

In order to evaluate the relationship between the concentration of welding fumes and cigarette smoke on the bronchopulmonary system function, a comparative study of spirometric measurements in 100 welders and 50 healthy volunteers was performed in an automobile manufacturing company. Two groups of workers were matched according to their age, height, smoking habit, years of service and soci...

متن کامل

بررسی منحنی های عملکرد ریوی در شاغلین کارخانه های تولید کننده محصولات سیمانی آزبستی

  Background and aims : Asbestos components are one of the most hazardous air pollutants that can cause a number of serious diseases in humanincluding asbestosis, lung cancer and mesothelioma . The main goal of this research was the assessment of occupational exposure effects with Asbestos fibers on pulmonary function and lung capacity disorders in worker of an Asbestos- cement pipe and plate m...

متن کامل

Investigation of the Relationship between Genetic Polymorphisms in GSTM1 and GSTT1 Genes and Susceptibility to Lung Functional Abnormalities in Workers Exposed to Air Pollutants at Isfahan Steel Plant

Introduction: Gaseous air pollutants can cause oxidative stress, which can lead to lung damage by inducing inflammation. Polymorphisms in the glutathione S-transferase (GST) gene are involved in the pathogenesis of many diseases, including lung disease. Two glutathione S-transferase Mu 1 (GSTM1) and glutathione S-transferase theta 1 (GSTT1) genes belong to this family, in which deletions occur ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 9 10  شماره 

صفحات  -

تاریخ انتشار 1996