Equipment, measurement and dose—a survey for therapeutic ultrasound
نویسندگان
چکیده
BACKGROUND Dosimetry for Ultrasound Therapy (DUTy) is a large international project which addresses the development of a metrological infrastructure for the determination of ultrasound exposure and dose to tissue. METHODS In order to seek the views of the wider therapy ultrasound community and to review dose and in situ exposure quantities that have been suggested or used previously, a web-based questionnaire containing a range of questions covering the type of ultrasound equipment that is used and the range of applications for which it has been developed was created at www.surveymonkey.com. This questionnaire was intended to cover any contemporary therapeutic ultrasound application (including physiotherapy, lithotripsy and drug delivery) and asked specific questions about quantification of in situ exposure and dose, especially as relevant to treatment planning, standardisation and/or regulation. RESULTS This paper summarises the 123 responses submitted between February and September 2014 to the questions on clinical applications, equipment, quality assurance (QA) and measurement and standards, as well as to those relating to an understanding of "dose" in the context of ultrasound. The full set of anonymous responses is available in an additional Excel file. CONCLUSIONS The results clearly demonstrate the need not only for further improvements in measuring devices and for measurement guidelines but also for a wider dissemination and higher awareness of existing standards. Whilst it is unlikely that a single definition of dose can be sufficient for all ultrasound treatment modalities, the answers clearly indicate that many aspects would benefit from clear definitions of relevant dose quantities and shed light on the preferred form of such definitions.
منابع مشابه
Therapeutic effects of high intensity focused ultrasound for in patients with benign uterine tumors with regard to lifestyle and obstetric characteristics
Background: The present investigation compared the decrease in the volume of benign tumor before and after High Intensity Focused Ultrasound (HIFU) treatment to evaluate the therapeutic effects of HIFU. in terms of Lifestyle and obstetric characteristics of in patients with Benign Uterine Tumors. Materials and Methods: To collect the data on each patients’ lifestyle and obstetric characteristic...
متن کاملGamma Dose Rate Measurement and Dose Rate Calculation for Sensitive Organs in the Vicinity of Hot Springs in Kerman Province
Introduction: All of the people worldwide are exposed to low levels of radiation. Cancer induction and genetic disorders are among the hazards of low level exposure. In some cases, radiation close to hot springs is higher than normal areas due to a high concentration and the decay products of Ra-226. Given the use of hot springs by the general public because of their therapeutic p...
متن کاملMeasurement of the Radiation Dose Rates of Patients Receiving Treatment with I-131 Using Telescopic Radiation Survey Meter
Introduction In order to discharge the patients receiving treatment with large radiation doses of 131I for thyroid cancer, it is necessary to measure and evaluate the external dose rates of these patients. The aim of the study was to assess a new method of external dose rate measurement, and to analyze the obtained results as a function of time. Materials and Methods In this study, a telescopic...
متن کاملEvaluation of Maximum Patient Skin Dose Arising from Interventional Cardiology Using Thermoluminescence Dosimeter in Mashhad, Iran
Introduction The increasing practice of interventional fluoroscopy in diagnosis and treatment of cardiovascular disease has risen attention to improve radiation protection of patients and cardiologists in these relatively high dose techniques. Therefore, nowadays there is an emphasis on the measurement of radiation dose received by patients and cardiologists arising from the relevant procedures...
متن کاملDestructive effects of therapeutic ultrasound and gold nanoparticles on a breast carcinoma tumor model in BALB/c mice
Background: Acoustic cavitation which occurs at high intensities of ultrasound waves can be fatal for tumor cells; however, it can be used to destroy cancer cells as an efficient therapeutic method. On the other hand, it is known that the existence of nanoparticles in a liquid decreases the acoustic cavitation onset threshold. Materials and Methods: In this work, the combined effects of therape...
متن کامل