The effect of chemical surface treatments of different denture base resins on the shear bond strength of denture repair.

نویسندگان

  • Y Sinasi Sarac
  • Duygu Sarac
  • Tolga Kulunk
  • Safak Kulunk
چکیده

STATEMENT OF PROBLEM Fracture of a repaired denture base often occurs at the junction of the base and repair materials rather than within these materials. PURPOSE The purpose of the study was to evaluate the shear bond strengths of 4 denture base acrylic resins following the use of 3 chemical solvents and to examine treated acrylic resin surfaces under a field emission scanning electron microscope (SEM). MATERIAL AND METHODS Forty discs (15 mm in diameter and 3 mm thick) were fabricated for each denture base material (a conventionally molded, heat-polymerized [Meliodent, M], an injection-molded, heat-polymerized [SR-Ivocap, I], and a microwave-polymerized [Acron MC, A]) repaired with an autopolymerizing acrylic resin (Meliodent), for a total of 120 specimens, processed according to manufacturers' instructions, embedded in acrylic resin blocks, and divided into 4 groups of 10. One of the groups served as control and had no surface treatment. In the 3 experimental groups, specimen surfaces were treated with chemical etchants by immersion in acetone (ac) for 30 seconds, in methylene chloride (mc) for 30 seconds, or in MMA (mo) for 180 seconds, respectively. Then autopolymerizing acrylic resin (Meliodent) was placed on the treated surfaces using a brass ring (6 mm in diameter and 2 mm in height) to confine the material to a standardized dimension. After 24 hours of storage at 37 degrees C, the shear bond strength (MPa) of the specimens was measured in a universal testing machine. A 2-way analysis of variance and the Tukey HSD test were performed to identify significant differences (alpha=.05). The nature of the failure was noted as adhesive, cohesive, or mixed. The effect of the chemical treatments on the surface of base resins was examined under an SEM. RESULTS Chemical treatments increased the bond strength of repair material significantly. Significant differences were found between the control and experimental groups (P<.001). In the control group, M showed the highest (16.7 MPa) bond strength, and A showed the lowest (9.4 MPa). No significant differences were detected between M (18.9 MPa) and A (19.9 MPa) with acetone treatment, or between M (19.3 MPa) and A (20.3 MPa) with methylene chloride treatment. The SEM observations showed that application of chemical etchants produced smoother surfaces than controls. CONCLUSION Chemical treatment prior to denture base repair showed significant improvement on the bond strength of the base materials. Although the microwave-polymerized acrylic resin, A, showed the lowest shear bond strength compared to the control groups, the highest percentage increase was obtained with A after chemical treatments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Shear Bond Strength of Denture Repair with Autopolymerizing Acrylic Resin Influenced by Three Surface Treatments

The repaired denture base material fractures at the interface of base and repair material. This study evaluated the effect of different chemical treatment of the surfaces on the shear bond strength of conventional heat-cured resin repaired with autopolymerized acrylic resin. The specimens were divided into four groups, 30 specimens each according to surface treatment by chemical etchants Group ...

متن کامل

Shear Bond Strength of Acrylic Denture Teeth to PMMA and Polyamide Denture Base Materials

Introduction: Detachment of denture teeth from denture base is one of the most common reasons for costly denture repairs .This study aimed at evaluating the bond strength of an acrylic denture tooth to polyamide injection-molded thermoplastic denture base material compared with three conventional polymethylmethacrylate (PMMA) denture base resins. Materials and Method: A total of 40 acrylic dent...

متن کامل

مقایسه تأثیر نوع دندان مصنوعی و Cyclic loading بر میزان استحکام باند در آکریل بیس دنچر خودبه‌خود پلیمریزه شونده

Background and Aims: Failure of bonding between artificial teeth and denture base material is a considerable problem for patients who wear dentures. According to the different impact of artificial teeth and different information about resistance force of mastication and also with deficiency in researchs, this study was designed to compare the bond strength of composite and acrylic artificial te...

متن کامل

Effect of surface treatment methods on the shear bond strength of auto-polymerized resin to thermoplastic denture base polymer

PURPOSE Polyamide polymers do not provide sufficient bond strength to auto-polymerized resins for repairing fractured denture or replacing dislodged denture teeth. Limited treatment methods have been developed to improve the bond strength between auto-polymerized reline resins and polyamide denture base materials. The objective of the present study was to evaluate the effect of surface modifica...

متن کامل

In-vitro Evaluation of Transverse Strength of Repaired Heat Cured Denture Base Resins without Surface Treatment and with Chemical and Mechanical Surface Treatment

BACKGROUND Denture repair involves joining two parts of a fractured denture with a denture repair material. Hence, a substantial repairing system for denture base fracture should be there to elude frequent fracture. MATERIALS AND METHODS Surface treatment of conventional heat cure denture base resin with different surface treatments (chemical ethyl acetate, and mechanical roughening with bur)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of prosthetic dentistry

دوره 94 3  شماره 

صفحات  -

تاریخ انتشار 2005