Kinetic-spectrophotometric method for the determination of trace amounts of bromide in seawater.

نویسندگان

  • Kanchana Uraisin
  • Toshio Takayanagi
  • Mitsuko Oshima
  • Duangjai Nacapricha
  • Shoji Motomizu
چکیده

A novel simple, sensitive and rapid kinetic-spectrophotometric method is proposed for the determination of trace amounts of bromide. The method is based on its catalytic effect on the oxidation of methylene blue (MB) by hydrogen peroxide in strongly acidic solution. The oxidation reaction is activated by large amounts of chloride and can be monitored spectrophotometrically by measuring the decrease in the absorbance of MB at 746 nm. The determination of bromide is performed by a fixed-time method at the first 100 s from the initiation of the reaction. Unlike other kinetic-spectrophotometric methods for the determination of bromide, the proposed method does not require heating the solution. Bromide can be determined in the range from 80 to 960 microg l(-1) with the detection limit of 35 microg l(-1). The relative standard deviation of ten replicate determination of 480 microg l(-1) bromide was 1.4%. The influence of potential interfering ions was studied. The proposed method was satisfactorily applied to the determination of bromide in seawater without interfering effect from chloride ion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of trace amounts of bromide by flow injection/stopped-flow detection technique using kinetic-spectrophotometric method.

A simple, sensitive and selective method for the determination of bromide in seawater by using a flow injection/stopped-flow detection technique was examined. The detection system was developed for a new kinetic-spectrophotometric determination of bromide in the presence of chloride matrix without any extraction and/or separation. The detection was based on the kinetic effect of bromide on the ...

متن کامل

Kinetic spectrophotometric determination of trace amounts of nitrite ion using potassium bromate-murexide mixture in acidic media

A new, simple, rapid, and cheap method for determination of trace amounts of nitrite ion is reported.Determination is based on reduction of bromate ion by nitrite ion, in the presence of murexide inacidic media. During reaction of bromate ion with nitrite ion, the reaction mixture is decolorized.The absorbance changes is then monitored spectrophotometricaly at 520 nm, at 25 °C. Dynamicrange of ...

متن کامل

KINETIC-SPECTROPHOTOMETRIC DETERMINATION OF TRACE AMOUNTS OF NITRITE BY THE REACTION OF METHYL ORANGE FORMATION

The composite diazotization coupling reaction of sulfanilic acid and N, Ndimethylaniline was used for the precise, accurate, and rapid determination of trace amounts of nitrite ion (0.02-3 µg/ml). The reaction was monitored spectrophotometrically by measuring the absorbance of the produced methyl orange at 510 nm by a fixed the method of 5.0 minutes. The relative standard deviation for the...

متن کامل

Kinetic-Spectrophotometric Determination of Track Amounts of Nitrite Ion Based on Its Reduction Reaction with Thionine in Acidic Media

A simple, sensitive and rapid method for determination of trace amounts of nitrite ion in real samples is reported. The reaction is initiated by adding known volumes of a nitrite ion solution of identified concentration to acidic solutions of thionine which causes decolorizaiton of reagent with time. The absorbance changes is then monitored spectrophotometrically at l...

متن کامل

Determination of ultra trace amount manganese (II) in water samples with the 1-(2-PyridylAzo)-2-Naphthol, (PAN) by the bromate ion in sulfuric acid with kinetic spectrophotometric method

A new kinetic spectrophotometic method for the determination of trace amount manganese(II) in Tea real samples has been described based on it s the catalytic effect on the oxidations of 1 - (2 – Pyridyl Azo) - 2 - Naphthol, (PAN), by potassium bromated in sulfuric acid. The reaction is followed spectrophotometrically by measuring the decrease in the absorbance at 547.5 nm. Under the optimum con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 68 3  شماره 

صفحات  -

تاریخ انتشار 2006