Determination of immunoglobulin G in bovine colostrum and milk by direct biosensor SPR-immunoassay.
نویسندگان
چکیده
An automated biosensor surface-plasmon resonance-based assay was developed for the determination of immunoglobulin G (IgG) in bovine milk and colostrum with either goat or rabbit antibovine IgG or protein G used as detecting molecule. The method is configured as a direct and nonlabeled immunoassay, with quantitation against an authentic IgG calibrant. Whole colostrum or milk is prepared for analysis by dilution into buffer. Analysis conditions, including ligand immobilization, flowrate, contact time, and regeneration, were optimized, and nonspecific binding was evaluated. Performance parameters included working range of 15-10 000 ng/mL, method detection limit of 0.08 mg/mL, overall instrument response reproducibility relative standard deviation (RSD(R)) of 0.47%, mean between-run RSD(R) of 10.5% for colostrum, and surface stability over 200 analyses. The proposed method was compared with independent alternative methods. The technique was applied to the measurement of IgG content during early lactation transition from colostrum to milk, as well as in consumer milk, colostrum, and hyperimmune milk powders.
منابع مشابه
Fast biosensor immunoassays for the detection of cows' milk in the milk of ewes and goats.
Two monoclonal antibodies (MAb) raised against bovine kappa-casein were developed and applied in an automated optical biosensor (Biacore 3000) to create easy and fast direct and inhibition biosensor immunoassays (BIA) for the detection of cows' milk in the milk of ewes and goats. With both assay formats, low limits of detection (<01%) and fast run times (around 5 min) were obtained. For sample ...
متن کاملDetection of antirotavirus immunoglobulins A, G, and M in swine colostrum, milk, and feces by enzyme-linked immunosorbent assay.
An enzyme-linked immunosorbent assay was developed to allow direct detection of class-specific antirotavirus antibodies. In colostrum and in milk, antirotavirus antibodies were found in the three immunoglobulin classes. Antirotavirus immunoglobulins G and M were predominant in colostrum, whereas antirotavirus immunoglobulin A was predominant in milk and feces.
متن کاملSurface Plasmon Resonance Investigations of Bioselective Element Based on the Recombinant Protein A for Immunoglobulin Detection
The developed surface plasmon resonance (SPR) biosensor based on the recombinant Staphylococcal protein A with an additional cysteine residue (SPA-Cys) used as a biorecognition component showed a good selectivity and sensitivity for the immunoglobulin detection. The developed biosensor with SPA-Cys-based bioselective element can also be used as a first step of immunosensor creation. The success...
متن کاملImmunoglobulin derived from bovine plasma as a replacement for colostrum in newborn lambs.
Newborn lambs (n = 45) at the Agricultural Research Institute of Northern Ireland were fed either 50 grams of commercial lamb milk replacer or 50 grams of commercial colostrum replacer (bovine origin) in 200 ml of water four times during the first 24 hours of life or were given ad libitum access to the ewe. Total plasma protein at 24 hours of age was highest in lambs allowed to suckle the ewe (...
متن کاملEffect of dietary IgG source (colostrum, serum, or milk-derived supplement) on the efficiency of Ig absorption in newborn Holstein calves.
This study was designed to compare the absorptive efficiency of IgG from a commercial bovine serum product (bovine serum), cow colostrum (positive control), and two commercial milk-derived IgG supplements (supplement 1 and supplement 2). Newborn Holstein calves, collected at birth and prior to the consumption of colostrum, were allotted to treatment by alternating birth order. Colostrum supplem...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of AOAC International
دوره 86 2 شماره
صفحات -
تاریخ انتشار 2003