A Comparison of Radiographic Film Densitometry Using a New Computerized Tool with a Digital Densitometer
نویسندگان
چکیده
OBJECTIVES The purpose of this study was to develop and test a new tool for radiographic densitometry by combining periapical films and aluminum step wedge. MATERIALS AND METHODS We reviewed 50 Kodak E-speed intraoral films. An aluminum step wedge consisting of 16 steps was constructed. Each step was 1mm×3m×10mm. The step wedge was exposed to varying exposure times, ranging from 0.05 second to 0.5 second, increasing in 0.05 second increments. Films were digitalized after processing and the MATLAB software algorithm was ran subsequently. Density of the films was measured again using a digital densitometer. In order to compare the two imaging techniques, three steps were selected. Output data from the MATLAB algorithm were compared with data obtained from the digital densitometer. RESULTS The new method could detect significant differences between subsequent exposure times in step 7, while the densitometer did that in steps 7 and 12. The new method's sensitivity in determining density changes was 5.26%, 84.1% and 93.02% in steps 2, 7, and 12 respectively. CONCLUSIONS Our new method has an acceptable sensitivity for determining density changes of at least 7 mmEq/Al.
منابع مشابه
ارزیابی دقت دانسیتومتری تصاویر دیجیتال غیر مستقیم
Statement of Problem: One of the major goals, in most dental researches, is to measure bone destruction or deposition due to the progression or regression of disease. Failure of human eyes to detect minor radiographic density changes resulted in more accurate methods such as optical densitometry and direct or indirect digital densitometry.Purpose: The aim of this study was to determine the accu...
متن کاملبررسی دقت دانسیتومتری اپتیک فیلم های رادیوگرافی و دانسیتومتری در سیستم رادیوویزیوگرافی به صورت In-vitro
Nowadays, bone mass estimation, through imaging methods, is widely used in metabolic diseases diagnosis and treatment. One of these methods is called "optical densitometry" which estimates bone density by measuring the intensity of the transmitted light on different parts of a radiographic image. Digital radiography systems act similarly by determining grey levels of the image. The aim of this ...
متن کاملDetection of Aortic Calcification during Vertebral Fracture Assessment (VFA) Compared to Digital Radiography
BACKGROUND Cardiovascular disease is the most common cause of mortality among post-menopausal women. Our objective was to determine whether or not lateral spine images obtained on a bone densitometer to detect prevalent vertebral fracture can also accurately detect radiographic abdominal aortic calcification (AAC), an important risk factor for cardiovascular disease independent of clinical risk...
متن کاملA study of densitometry comparison among three radiographic processing solutions
ABSTRACT Background: The radiographic image accuracy depends on the X-ray film information visibility. Good visibility is found by good contrast. Radiation exposure parameters (kVp, mAs) and film processing conditions have impact on contrast. In dentistry radiography machines, exposure time and processing procedure are set by radiographer. No optimized exposure time and process...
متن کاملHigh-resolution densitometry: analysis of stained albumin bands as a model for electrophoresis of serum proteins.
In discussing the principles of quantitative analysis in thin-layer media, we show that requirements for quantitative analysis are not satisfied when stained protein electrophoretic bands are scanned with a conventional rectangular-slit densitometer. We investigated a high-resolution densitometer based on a linear photodiode array as an alternative analytical tool, using stained electrophoretic...
متن کامل