The EN584 Standard for the Classification of Industrial Radiography Films and its Use in Radiographic Modelling
نویسنده
چکیده
One of the problems in modelling radiographic inspections concerns the film characteristics as the last step in the radiographic modelling chain, throughout which the energy deposited by the incoming radiation is to be converted to a grey value. This conversion depends not only on the total dose absorbed by the film, but also on the radiation’s spectrum and to a lesser extent also on the incidence angle of the incoming radiation. Models trying to take all or most of these influential parameters into account inevitably lead to complex and proprietary film characterizations, and in particular require information generally not available in the film data sheets provided by the manufacturers. The recent EN584 standard for the classification of film systems for industrial radiography proposes a pragmatic and in many cases sufficient classification in terms of the dose required to obtain optical density 2, and the gradient of an optical density vs. required dose at optical densities 2 and 4. In this paper, we discuss different ways to implement an EN584-compliant film model.
منابع مشابه
Using the EN584-1 film characterization in radiographic modelling
One of the problems in modelling radiographic inspections concerns the film characteristics as the last step in the radiographic modelling chain, throughout which the energy deposited by the incoming radiation is to be converted to a grey value. This conversion depends not only on the total dose absorbed by the film, but also on the radiation’s spectrum and to a lesser extent also on the incide...
متن کاملSensitometric characteristics of D-, E- and F-speed dental radiographic films in manual and automatic processing
BACKGROUND: The purpose of this study was to evaluate the sensitometric characteristics of Ultraspeed, Ektaspeed Plus and Insight dental radiographic films using manual and automatic processing systems. METHODS: In this experimental invitro study, an aluminum step-wedge was used to construct characteristic curves for D-, E- and F-speed radiographic films (Kodak Eastman, Rochester, USA). All fil...
متن کاملMicrobiological analysis of radiographic films and tubes (2001in private and public dental radiographic centres in Yazd(
Microbiological analysis of radiographic films and tubes (2001in private and public dental radiographic centres in Yazd( oddini Ardakani* - Dr. S. Karamzadeh Motlagh** zDr. F. E * - Assistant professor of Oral Radiology Dept. Faculty of Dentistry Yazd University of Medical Sciences. ** - Dentist. Background and aim: In dental radiography, there are specific potentials to transmit infection. T...
متن کاملRadiographic images repeats in Bandar Abbas teaching hospitals, Iran
Introduction: One of the obvious problems regarding radiography considered to be the malfunction of films and repeating the test, which leads to increase was carried out in hospital costs and irreparable radiation. The present research at shahid mohammadi teaching hospital of Bandar-Abbas, Iran. Methods: This decretive cross-sectional study was done within six months in shahid mohammadi and chi...
متن کاملRadiation Safety Analysis, 2 Models of Industrial Radiography Techniques in Tubes Testing Using SuperMc 3.2
In this article, we used SuperMc 3.2 Software for have studied two models of welding radiographic techniques that are more common in radiographs (Dobell Walls and Single Image (DWSI) and Single Wall and Single Image (SWSI) technique) , without the use of a collimator and in terms of radiation risk and radiation safety. According to results, Due to the lack of a collimator, the risk of radiation...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2007