Renal volumetry with magnetic resonance imaging
نویسندگان
چکیده
BACKGROUND No gold standard exists for renal volumetry in vivo. PURPOSE To devise and evaluate segmentation methods on magnetic resonance imaging (MRI) datasets. MATERIAL AND METHODS Five combinations of MRI pulse sequences and measuring methods were used to measure the renal volumes of five men aged 54-72 years scanned before autologous renal stem cell transplantation and three, six, and 12 months post transplantation. RESULTS Renal volume did not change after stem cell transplantation. The results varied considerably: the reproducibility (coefficient of variation) was 4.0-6.0% and measurements took 1-13 min per kidney. Manual segmentation of images from the volumetric interpolated breath-hold examination (VIBE) without fat saturation sequence provided best reproducibility but was time-consuming. Use of the ellipsoid formula from half Fourier acquisition single shot turbo spin echo (HASTE) provided the fastest measurement, but resulted in lower reproducibility. CONCLUSION Renal volumetry based on images from the pulse sequence VIBE without fat saturation acquired using an out-of-phase TE may be investigated further, possibly in combination with the quick ellipsoid formula.
منابع مشابه
Volumetry may predict early renal function after nephron sparing surgery in solitary kidney patients
We investigate the impact of the residual kidney volume measured by tumor volumetry on preoperative imaging in predicting post-operative renal function. Nephron sparing surgery (NSS) in renal cell carcinoma (RCC) is the standard treatment for T1 kidney tumors. Resection of kidney tumors in solidary kidneys needs precise preoperative counseling of patients regarding post-operative renal function...
متن کاملAdvanced techniques in magnetic resonance imaging of the brain in children with ADHD.
Attention deficit hyperactivity disorder (ADHD) affects about 5% of school-aged child. Previous published works using different techniques of magnetic resonance imaging (MRI) have demonstrated that there may be some differences between the brain of people with and without this condition. This review aims at providing neurologists, pediatricians and psychiatrists an update on the differences bet...
متن کاملStatic Coil Design Considerations for the Magnetic Resonance Imaging
One of the main challenges in developing magnetic resonance imaging (MRI) systems is to create a static coil that needs to generate magnetic field density along with the characteristics of optimal homogeneity and magnitude size. To do this, two N42 Block PMs are used and the iron core is designed and optimized in accordance with the dimensions of PM pieces using ANSYS Maxwell software. Then, al...
متن کاملImproved reproducibility of LV volumetry and infarct size measurement using a standardized evaluation protocol for cardiac magnetic resonance imaging
Purpose LV volumetry and infarct size measurement using cardiac magnetic resonance imaging (MRI) is the reference standard to non-invasively measure and to quantify cardiac volumes, function and infarct size. We have observed a high variability of cardiac MRI measurements, if inexperienced observers evaluated the MRI data. The purpose of the study was to analyze the reproducibility of cardiac M...
متن کاملANALYTICAL STUDY OF EFFECT OF BILAYER INORGANIC AND ORGANIC COATING AROUND THE IRON OXIDE NANOPARTICLES ON MAGNETIC RESONANCE IMAGING CONTRAST
Background & Aims: In recent years, iron oxide nanoparticles have been used in contrast-enhanced magnetic resonance imaging for diagnosing a wide range of diseases. In order to provide biocompatibility and prevent the toxicity of the nanoparticles, using organic or inorganic coating around these nanoparticles is important for their application. The aim of this study is to investigate the effect...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 6 شماره
صفحات -
تاریخ انتشار 2017