The effect of thin, thick, and normal corneas on Goldmann intraocular pressure measurements and correction formulae in individual eyes.

نویسندگان

  • Serena J K Park
  • Ghee Soon Ang
  • Simon Nicholas
  • Anthony P Wells
چکیده

OBJECTIVE To evaluate the usefulness of the central corneal thickness (CCT)-based correction formulae for stratified CCT groups, with intraocular pressure (IOP) from the Pascal dynamic contour tonometer (PDCT) as the reference standard. DESIGN Retrospective case series. PARTICIPANTS Two hundred eighty-nine patients attending a specialist glaucoma practice and a mixture of normal subjects and subjects with confirmed glaucomatous optic neuropathy. METHODS Intraocular pressure was measured using PDCT, Goldmann applanation tonometry (GAT), and the Ocular Response Analyzer (ORA; Reichert Corp, Buffalo, NY). The GAT readings were obtained before automated readings and were adjusted for CCT using 4 different correction formulae. Discrepancies between GAT and CCT-corrected GAT readings were evaluated after stratification into thin, intermediate, and thick CCT groups. The IOP measurements from GAT, the ORA, and CCT-adjusted IOP were compared against PDCT IOP measurements using Bland-Altman analysis. MAIN OUTCOME MEASURES Mean, 95% limits of agreement, and proportion of patients with IOP difference of 20% or more between PDCT IOP and each of GAT IOP, Goldmann-correlated IOP (IOPg), corneal-compensated IOP (IOPcc), and adjusted IOP using CCT-based correction formulae. RESULTS Average PDCT IOP values were higher than GAT, IOPg, IOPcc, and CCT-adjusted IOP. The GAT IOP readings demonstrated poor agreement with PDCT IOP (95% limits of agreement, ± 4.7 mmHg); however, IOPg, IOPcc, and adjustment of GAT IOP with CCT-based formulae resulted in even poorer agreement (range of 95% limits of agreement, ± 5.1 to 6.7 mmHg). If PDCT was used as the reference standard, there was a 26% to 39% risk of making an erroneous IOP adjustment of magnitude of 20% or more at all levels of CCT. This risk was greatest in the patients with thicker corneas (CCT, ≥568 μm). CONCLUSIONS Adjusting IOP using CCT-based formulae resulted in poorer agreement with PDCT IOP when compared with unadjusted G AT IOP. If PDCT is the closest measure we have to intracameral IOP, there is a risk of creating clinically significant error after adjustment of GAT IOP with CCT-based correction formulae, especially in thicker corneas. This study suggests that although CCT may be useful in population analyses, CCT-based correction formulae should not be applied to individuals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea

Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...

متن کامل

Tono-Pen tonometry in normal and in post-keratoplasty eyes.

Oculab Tono-Pen tonometry was compared with Goldmann applanation tonometry in 82 eyes of 82 patients with normal corneas and in 54 eyes of 54 patients who had undergone penetrating keratoplasty and whose corneas did not preclude the use of Goldmann tonometer. We found that the intraocular pressure (IOP) in 48% of the eyes with normal corneas and in 57% after keratoplasty has different measureme...

متن کامل

Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer, and Tono-Pen.

PURPOSE To compare intraocular pressure (IOP) measurements of the Ocular Blood Flow (OBF) pneumotonometer, Goldmann applanation tonometer, and Tono-Pen in eyes with normal corneas of various thicknesses. METHODS IOP was measured with an OBF pneumotonometer, Tono-Pen and Goldmann applanation tonometer in random order in 181 eyes with normal corneas. Central corneal thickness (CCT) was measured...

متن کامل

Effects of latanoprost and pilocarpine combination on the intraocular pressure and pupil size of normal rabbits

The aim of this study was to determine the combination effect of latanoprost and pilocarpine on theintraocular pressure and pupil size in normal rabbits. In this study, 18 rabbits were randomized to threegroups of 6 animals each. The right eyes of rabbits in group 1 were treated topically with latanoprost, ingroup 2 with pilocarpine and in group 3 with latanoprost and pilocarpine. The left eyes...

متن کامل

Goldmann and error correcting tonometry prisms compared to intracameral pressure

BACKGROUND Compare Goldmann applanation tonometer (GAT) prism and correcting applanation tonometry surface (CATS) prism to intracameral intraocular pressure (IOP), in vivo and in vitro. METHODS Pressure transducer intracameral IOP was measured on fifty-eight (58) eyes undergoing cataract surgery and the IOP was modulated manometrically to 10, 20, and 40 mmHg. Simultaneously, IOP was measured ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ophthalmology

دوره 119 3  شماره 

صفحات  -

تاریخ انتشار 2012