Histopathological changes in the human larynx following expanded polytetrafluroethylene (Gore-Tex®) implantation

نویسندگان

  • K Rajkumar
  • HS Khalil
  • M Elloy
  • E Sheffield
  • DL Baldwin
چکیده

BACKGROUND: Expanded polytetrafluroethelyne (e PTFE, Gore-Tex(R)) has been advocated as an implant material for medialization of the vocal fold. Animal studies involving rabbits and a porcine model have demonstrated host tolerance of the implant. There have been no reports describing the histological changes in a human laryngectomy specimen with a Gore-Tex implant. CASE PRESENTATION: The histological findings in a laryngectomy specimen of a patient previously implanted with e PTFE for medialization of a paralyzed vocal fold following excision of a vagal neurofibroma were studied.Histopathology revealed a mild foreign-body giant cell granulomatous reaction with some associated fibrosis. The granulomatous response was limited to the periphery of the Gore-Tex and although it closely followed the profile of the material it did not encroach into or significantly break up the material. There was no significant neutrophilic or lymphocytic inflammation. CONCLUSIONS: Our findings are consistent with the animal models confirming that Gore-Tex implantation does not result in a significant granulomatous reaction in the human larynx over a 13-month period. Moreover, there is no evidence of resorption or infection. Further, the lack of lymphocytes in association with the granulomas indicates that there is no significant immunological hypersensitivity. Histologically, the slight permeation by connective tissue is similar to that seen in Gore-Tex vascular and cardiac implants. The degree of the slight giant cell response appears to be dependent on the profile of the material; a sharp edge incited more of a response than a flat surface.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Revision medialization thyroplasty with hydroxylapatite implants.

INTRODUCTION Medialization thyroplasty is a useful tool in the management of dysphonia and dysphagia with aspiration secondary to unilateral vocal fold impairment. A variety of implant materials have been used for medialization thyroplasty including silicone elastomer (Silastic, Dow Corning Corporation, Midland, MI), expanded polytetrafluoroethylene (Gore-Tex, Gore, Newark, DE), and hydroxylapa...

متن کامل

ترمیم حفره استخوانی ایجاد شده در استخوان پاریتال خرگوش به وسیله پودر جایگزین استخوان (Neo-Os) با و بدون محافظ

Nowadays, different materials have been used for regeneration of interosseous defects and Neo-Os is one of them. The objective of this study was to evaluate histologically the influence of Neo-Os® particles on bone regeneration using rabbit caivarias defects with and without protection of Gore-Tex® barrier membrane. A cutaneous- periosteal incision and flap was made on the forehead of 32 rabbit...

متن کامل

Results of bony chest wall reconstruction with expanded polytetrafluoroethylene soft tissue patch.

PURPOSE The early and long-term outcomes of bony chest wall reconstruction with expanded polytetrafluoroethylene (Gore-Tex) soft tissue patch remain a concern. No clinical study has reported the shrinkage of Gore-Tex following reconstruction to date. METHODS Thirty-seven patients who underwent bony chest wall reconstruction from 1994 to 2012 were retrospectively reviewed. Postoperative chest ...

متن کامل

ارزیابی و مقایسه عوارض وتمامیت فیستول شریانی- وریدی باگرافت گورتکس 6 و 8 میلی‌متری در اندام فوقانی و مقایسه آن‌ها با گرافت گورتکس 8 میلی‌متری اندام تحتانی در یک سال اول پس از عمل

Background & Aims: This study was done in hem dialysis patients who referred to Imam Khomeini hospital of Urmia for insertion of arterial -venous fistula with Gore-tex, in whom there was not possibility of natural fistula. Objectives were assessment and comparison of complications and patency of arterial-venous fistulas was done with 6 and 8 mm Gore-tex graft in the upper limb and comparison of...

متن کامل

Nasal augmentation using Gore-Tex. A 10-year experience.

OBJECTIVE To determine on an ongoing basis the safety and efficacy of expanded polytetrafluoroethylene (Gore-Tex soft tissue patch and preformed nasal implants) as an implant in rhinoplasty. DESIGN A retrospective study of 309 consecutive patients who underwent rhinoplasty, including augmentation with Gore-Tex, during a 10-year period. SETTING Two major academic medical centers and 2 privat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC Ear, Nose and Throat Disorders

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2005