Monitoring tricyclic antidepressant concentrations in serum by fluorescence polarization immunoassay compared with gas chromatography and HPLC.

نویسندگان

  • M L Rao
  • U Staberock
  • P Baumann
  • C Hiemke
  • A Deister
  • C Cuendet
  • M Amey
  • S Härtter
  • M Kraemer
چکیده

The fluorescence polarization immunoassay (FPIA) developed by Abbott to diagnose intoxication with tricyclic antidepressants was adapted for therapeutic drug monitoring and validated with chromatograpic methods to investigate its potential for this use. We compared serum concentrations of tricyclic antidepressants in vivo and in vitro obtained by FPIA with those by gas chromatography and HPLC. For amitriptyline, imipramine, clomipramine, and doxepin, the detection limit of the FPIA was 72, 71, 64, and 72 nmol/L (approximately 20 micrograms/L), respectively; that by gas chromatography was 18, 18, and 16 nmol/L (approximately 5 micrograms/L) for amitriptyline, imipramine and clomipramine, respectively; with HPLC the lower limit of detection for doxepin was 36 nmol/L (10 micrograms/L). The intra- and interassay CVs ranged from 3% to 6%. In patients being treated with amitriptyline, imipramine, clomipramine, and doxepin, at steady-state the correlation coefficients between FPIA and GC/HPLC results for split samples were 0.95, 0.92, 0.90 and 0.70, respectively. However, the slopes were close to unity only for amitriptyline and doxepin, being 0.6 for imipramine and 1.9 for clomipramine.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Liquid chromatography and fluorescence polarization immunoassay methods compared for measuring flecainide acetate in serum.

We analyzed 99 patients' serum samples for concentrations of a new antiarrhythmic agent, flecainide acetate, by fluorescence polarization immunoassay (FPIA) and "high-performance" liquid chromatography (HPLC). Within-day and between-day coefficients of variation at concentrations in the low and high ends of the therapeutic range were less than 7% for HPLC and less than 9% for FPIA. There was no...

متن کامل

Vancomycin monitoring in term newborns: comparison of peak and trough serum concentrations determined by high performance liquid chromatography and fluorescence polarization immunoassay.

INTRODUCTION Peak and trough serum concentrations of vancomycin were determined in term newborn infants with confirmed or suspected Staphylococcus sp sepsis by high performance liquid chromatography and flourescence polarization immunoassay. OBJECTIVE To statistically compare the results of the high performance liquid chromatography and flourescence polarization immunoassay techniques for mea...

متن کامل

Determination of blood sirolimus concentrations in liver and kidney transplant recipients using the Innofluor® fluorescence polarization immunoassay: Comparison with the microparticle enzyme immunoassay and high-performance liquid chromatography-ultraviolet method

BACKGROUND Although high-performance liquid chromatography (HPLC) is the method of choice for blood sirolimus determination, the microparticle enzyme immunoassay (MEIA) run on the IMx analyser is widely used in therapeutic monitoring of this immunosuppressant agent. The aim of our study was to evaluate the possible determination of sirolimus using the fluorescence polarization immunoassay (FPIA...

متن کامل

Comparison of cyclosporin G (Nva2-cyclosporin) concentrations measured in whole blood by monoclonal fluorescence polarization immunoassay, monoclonal radioimmunoassay, and HPLC.

Two commercial monoclonal immunoassays for monitoring cyclosporin A were used to measure whole-blood concentrations of the immunosuppressant cyclosporin G (CsG) in renal transplant patients. We performed a three-way comparison of these two immunoassays and HPLC. Although the two immunoassays agreed favorably, both the monoclonal fluorescence polarization immunoassay and the monoclonal RIA yield...

متن کامل

Comparison of plasma total homocysteine measurements in 14 laboratories: an international study.

BACKGROUND Information on interlaboratory variation and especially on methodological differences for plasma total homocysteine is lacking. METHODS We studied 14 laboratories that used eight different method types: HPLC with electrochemical detection (HPLC-ED); HPLC with fluorescence detection (HPLC-FD) further subdivided by type of reducing/derivatizing agent; gas chromatography/mass spectrom...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 40 6  شماره 

صفحات  -

تاریخ انتشار 1994