Impact of respiratory motion on breast tangential radiotherapy using the field-in-field technique compared to irradiation using physical wedges
نویسندگان
چکیده
BACKGROUND This study aimed to evaluate whether the field-in-field (FIF) technique was more vulnerable to the impact of respiratory motion than irradiation using physical wedges (PWs). PATIENTS AND METHODS Ten patients with early stage breast cancer were enrolled. Computed tomography (CT) was performed during free breathing (FB). After the FB-CT data set acquisition, 2 additional CT scans were obtained during a held breath after light inhalation (IN) and light exhalation (EX). Based on the FB-CT images, 2 different treatment plans were created for the entire breast for each patient and copied to the IN-CT and EX-CT images. The amount of change in the volume of the target receiving 107%, 95%, and 90% of the prescription dose (V107%, V95%, and V90%, respectively), on the IN-plan and EX-plan compared with the FB-plan were evaluated. RESULTS The V107%, V95%, and V90% were significantly larger for the IN-plan than for the FB-plan in both the FIF technique and PW technique. While the amount of change in the V107% was significantly smaller in the FIF than in the PW plan, the amount of change in the V95% and V90% was significantly larger in the FIF plan. Thus, the increase in the V107% was smaller while the increases in the V95% and V90% were larger in the FIF than in the PW plan. CONCLUSIONS During respiratory motion, the dose parameters stay within acceptable range irrespective of irradiation technique used although the amount of change in dose parameters was smaller with FIF technique.
منابع مشابه
Dosimetric comparison of whole breast radiotherapy using field in field and conformal radiotherapy techniques in early stage breast cancer
Background: We aimed to compare field-in-field technique (FIF) with conformal tangential field radiotherapy (CRT) in terms of dosimetric benefits for early stage breast cancer radiotherapy. Materials and Methods: Twenty consecutive left-side breast cancer patients who underwent breast-conserving surgery were included to the study. For each patient, two different treatment plans were cr...
متن کاملEstimation of the thyroid secondary cancer risk on the patient of standard breast external beam radiotherapy
Introduction: The purpose of this study was to estimate the secondary cancer risk of thyroid for standard radiotherapy methods which are commonly used for breast cancer patients. Materials and Methods: Sixty-four breast cancer patients (their age range was around 50 years old) who referred to Seyed- Al- Shohada hospital (Isfahan, Iran) were included in this ...
متن کاملOptimum reckoning of contra lateral breast dose using physical wedge and enhanced dynamic wedge in radiotherapy treatment planning system
Background: It was intended to investigate the effect of physical wedge (PW) and enhanced dynamic wedges (EDW) on contralateral breast dose during primary breast irradiation in radiotherapy treatment, using high energy photon beams. Materials and Methods: The Varian’s Clinac dual mode linear accelerator model 2100 C/D and Siemen’s Primus accelerators were used for radiation doses wi...
متن کاملOptimization of tangential fields arrangement in the breast cancer 3D conformal radiation therapy
Introduction: The incidence of breast cancer increases with the rate of 1-2% at the world. Radiation therapy is one of the available choices for breast cancer treatment. The single isocentre half-beam block technique is considered as a standard technique to avoid hot and cold spots within the PTV. The major advantage of half beam technique is that the both contralateral breast...
متن کاملEvaluation of regional nodes irradiation during breast cancer radiotherapy
Background: The purpose of this study was to evaluate nodal irradiation with conventional three-field's technique. Materials and Methods: Fifty patients with breast cancer were enrolled in this study. Computed tomography scans in the supine treatment position were imported into a treatment planning system. Levels I-III axillary and supraclavicular nodes were identified and their depths to the a...