Cardiac Output Monitoring by Pulse Contour Analysis, the Technical Basics of Less-Invasive Techniques
نویسنده
چکیده
Routine use of cardiac output (CO) monitoring became available with the introduction of the pulmonary artery catheter into clinical practice. Since then, several systems have been developed that allow for a less-invasive CO monitoring. The so-called "non-calibrated pulse contour systems" (PCS) estimate CO based on pulse contour analysis of the arterial waveform, as determined by means of an arterial catheter without additional calibration. The transformation of the arterial waveform signal as a pressure measurement to a CO as a volume per time parameter requires a concise knowledge of the dynamic characteristics of the arterial vasculature. These characteristics cannot be measured non-invasively and must be estimated. Of the four commercially available systems, three use internal databases or nomograms based on patients' demographic parameters and one uses a complex calculation to derive the necessary parameters from small oscillations of the arterial waveform that change with altered arterial dynamic characteristics. The operator must ensure that the arterial waveform is neither over- nor under-dampened. A fast-flush test of the catheter-transducer system allows for the evaluation of the dynamic response characteristics of the system and its dampening characteristics. Limitations to PCS must be acknowledged, i.e., in intra-aortic balloon-pump therapy or in states of low- or high-systemic vascular resistance where the accuracy is limited. Nevertheless, it has been shown that a perioperative algorithm-based use of PCS may reduce complications. When considering the method of operation and the limitations, the PCS are a helpful component in the armamentarium of the critical care physician.
منابع مشابه
A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis
Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...
متن کاملCardiac output monitoring: a contemporary assessment and review.
OBJECTIVE An increasing number of minimally or noninvasive devices are available to measure cardiac output in the critical care setting. This article reviews the underlying physical principles of these devices in addition to examining both animal and human comparative studies in an effort to allow clinicians to make informed decisions when selecting a device to measure cardiac output. DATA SO...
متن کاملLess invasive determination of cardiac output from the arterial pressure by aortic diameter-calibrated pulse contour.
BACKGROUND Cardiac output by modelflow pulse contour method can be monitored quantitatively and continuously only after an initial calibration, to adapt the model to an individual patient. The modelflow method computes beat-to-beat cardiac output (COmf) from the radial artery pressure, by simulating a three-element model of aortic impedance with post-mortem data from human aortas. METHODS In ...
متن کاملAccuracy of cardiac output measurements with pulse contour analysis (PulseCO) and Doppler echocardiography during off-pump coronary artery bypass grafting.
BACKGROUND AND OBJECTIVE During off-pump coronary bypass grafting, surgical manipulation and dislocation of the heart may cause cardiovascular instability. Monitoring of cardiac output facilitates intraoperative haemodynamic management but pulmonary artery catheters are often considered too invasive. Pulse contour analysis and transoesophageal echocardiography could serve as alternatives, but t...
متن کاملLack of agreement between esophageal doppler cardiac output measurements and continuous pulse contour analysis during off-pump cardiac surgery
Objective: Transesophageal echo-Doppler cardiac output as well as arterial pulse contour analyses cardiac output are increasingly used for cardiac output monitoring. No data are available whether both techniques may be used interchangeably in patients undergoing cardiac surgery. Design: Prospective, observational study Setting: Operating rooms of a university affiliated hospital. Patients: 30 p...