Active humidification with Boussignac CPAP: in vitro study of a new method.
نویسندگان
چکیده
OBJECTIVE To carry out an in vitro study of Boussignac CPAP valve performance with a new humidification method, using a heated humidifier. METHODS Two heated humidifiers were evaluated: Fisher & Paykel MR850, and Covidien Kendall Aerodyne 2000. Baseline measurements were taken in all experimental conditions without humidification. The Boussignac valve was adapted to the input of the humidification chamber. The system was connected to a test lung to assess the degree of pressurization. Hygrometric and pressure measurements were performed with the following gas flows: 10, 20, 30 and 40 L/min. RESULTS The mean values of pressure generated by the Boussignac valve were 1.99 ± 0.02, 6.97 ± 0.05, 16.61 ± 0.08 and 21.24 ± 0.08 cm H2O, 10, 20, 30 and 40 L/min, respectively, no differences being detected between study groups. Overall absolute humidity was significantly greater with a heated humidifier than without humidification (range 40.01 ± 0.57-25.46 ± 0.49 compared to 0.16 ± 0.13 mgH2O/L, P < .001). Absolute humidity was significantly higher in Kendall Aerodyne 2000 compared to MR850, regardless of the selected temperature and flow (P < .001). CONCLUSIONS This new method of Boussignac CPAP humidification yielded humidity values above 25 mg H2O/L regardless of the heated humidifier and flow used. Pressurization values remained constant in each experimental situation and were not influenced by adding humidification. These data open up the possibility of using Boussignac CPAP on different types of patients, with different interfaces and for long periods of time.
منابع مشابه
Aerosol delivery and humidification with the Boussignac continuous positive airway pressure device.
BACKGROUND A simple method for effective bronchodilator aerosol delivery while administering continuing continuous positive airway pressure (CPAP) would be useful in patients with severe bronchial obstruction. OBJECTIVE To assess the effectiveness of bronchodilator aerosol delivery during CPAP generated by the Boussignac CPAP system and its optimal humidification system. METHODS First we a...
متن کاملNoninvasive CPAP with face mask: comparison among new air-entrainment masks and the Boussignac valve.
BACKGROUND The performances of 2 noninvasive CPAP systems (high flow and low flow air-entrainment masks) were compared to the Boussignac valve in 3 different scenarios. METHODS Scenario 1: pneumatic lung simulator with a tachypnea pattern (tidal volume 800 mL at 40 breaths/min). Scenario 2: Ten healthy subjects studied during tidal breaths and tachypnea. Scenario 3: Twenty ICU subjects enroll...
متن کاملEffect of Heated Humidification on CPAP Therapy Adherence in Subjects With Obstructive Sleep Apnea With Nasopharyngeal Symptoms.
BACKGROUND The addition of heated humidification to CPAP has been shown to improve nasal adverse effects in subjects with obstructive sleep apnea (OSA). However, current data regarding improvement in CPAP adherence is conflicting. Furthermore, there are no data from a tropical climate area with a high humidity level. METHODS In this prospective randomized crossover study conducted in Thailand...
متن کاملComparison of haemodynamic effects of noninvasive ventilation delivered via ResQGARD and CPAP boussignac masks.
UNLABELLED Noninvasive ventilation (NIV) is a technique of mechanical ventilation which does not require invasive airway management, i.e. intubation or tracheostomy. In emergency medicine Continuous Positive Airway Pressure (CPAP) is used often. A new method of NIV is Impedance Threshold Device (ITD). Breathing through an ITD is utilized to raise blood pressure in hypotensive patients. AIM OF...
متن کاملPneumatic performance of the Boussignac CPAP system in healthy humans.
BACKGROUND The Boussignac continuous positive airway pressure (CPAP) device effectively treats acute pulmonary edema, but data on airway pressure with the Boussignac CPAP system are sparse. OBJECTIVE To evaluate the Boussignac CPAP system's ability to maintain stable inspiratory and expiratory pressure levels, and to evaluate perceived exertion during breathing with the Boussignac CPAP system...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Respiratory care
دوره 58 4 شماره
صفحات -
تاریخ انتشار 2013