Minimal inhibitory effect of male urine on detection of Chlamydia trachomatis by Roche Amplicor PCR.
نویسندگان
چکیده
A total of 1120 specimens of fresh urine from male patients was tested for Chlamydia trachomatis with the Roche Amplicor PCR Kit and an in-house PCR assay. The in-house PCR had an internal control to monitor inhibitory effects of clinical specimens on the PCR assay. All urine samples were processed within 24-48 h of collection and DNA was extracted on the same day that the assays were performed. Specimens that gave discrepant PCR results were tested by a reference laboratory with both the Roche Amplicor kit and their in-house PCR assay. Of the 1120 samples, 174 gave positive results in both assays and 942 gave negative results in both assays. Only one specimen showed an inhibitory effect on the in-house PCR assays, as indicated by failure to produce the internal control PCR product. This specimen gave negative results by both assays. There were four discrepant results in the two PCR assays. One was a false negative result obtained with the Roche Amplicor kit and the remaining three discrepant results could not be resolved because there was an insufficient quantity of specimen. This study demonstrated that the Roche Amplicor kit could effectively detect C. trachomatis in urine specimens from this population of male patients with negligible inhibition of PCR.
منابع مشابه
Detection of Chlamydia trachomatis infections in women by Amplicor PCR: comparison of diagnostic performance with urine and cervical specimens.
We used the Roche Amplicor PCR assay to compare urine and cervical swabs as sample material in the detection of Chlamydia trachomatis causing genital infections. The diagnostic performance of Amplicor PCR was compared with that of cell culture and the Gen-Probe PACE 2 assay with cervical specimens. If discrepant from other results, the specimens negative by PCR were diluted and reanalyzed to re...
متن کاملComparison between the LCx Probe system and the COBAS AMPLICOR system for detection of Chlamydia trachomatis and Neisseria gonorrhoeae infections in patients attending a clinic for treatment of sexually transmitted diseases in Amsterdam, The Netherlands.
Two assays for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae were compared: the LCx Probe system (the LCx system; Abbott Diagnostic Laboratories, North Chicago, Ill.) and the COBAS AMPLICOR C. trachomatis/N. gonorrhoeae system (the COBAS AMPLICOR system; Roche Diagnostic Systems, Branchburg, N.J.). Endocervical swab specimens, male urethral swab specimens, and female and male...
متن کاملMulticenter evaluation of the AMPLICOR and automated COBAS AMPLICOR CT/NG tests for detection of Chlamydia trachomatis.
The fully automated COBAS AMPLICOR CT/NG and semiautomated AMPLICOR CT/NG tests were evaluated in a multicenter trial for the ability to detect Chlamydia trachomatis infections. Test performance compared to that of culture was evaluated for 2,236 matched endocervical swab and urine specimens obtained from women and for 1,940 matched urethral swab and urine specimens obtained from men. Culture-n...
متن کاملDirect Detection of Chlamydia trachomatis in Urine
Screening for Chlamydia trachomatis infection in men has traditionally been limited to men who present with urethral symptoms, thereby limiting the detection of asymptomatic chlamydia infection in men. In order to effectively screen both symptomatic and asymptomatic men, we evaluated a newly developed polymerase chain reaction (PCR) assay, Amplicor C. trachomatis, from Roche Molecular Systems f...
متن کاملDiagnosis by AMPLICOR PCR of Chlamydia trachomatis infection in urine samples from women and men attending sexually transmitted disease clinics.
Screening of urine specimens from men for Chlamydia trachomatis infection by a commercial PCR assay (AMPLICOR C. trachomatis Test; Roche Diagnostic Systems, Inc., Branchburg, N.J.) is a sensitive and specific noninvasive diagnostic assay. Since screening of women for C. trachomatis infection with the AMPLICOR C. trachomatis Test has been limited to use with endocervical swab specimens, we condu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of medical microbiology
دوره 48 2 شماره
صفحات -
تاریخ انتشار 1999