MRI of the human eye using magnetization transfer contrast enhancement.

نویسندگان

  • M J Lizak
  • M B Datiles
  • A H Aletras
  • P F Kador
  • R S Balaban
چکیده

PURPOSE To determine the feasibility of using magnetization transfer contrast-enhanced magnetic resonance imaging (MRI) to track cataractous lens changes. METHODS A fast spin-echo sequence was modified to include a magnetization transfer contrast (MTC) preparation pulse train. This consisted of twenty 8.5-msec sinc pulses, 1200 Hz upfield from the water resonance and 1.2-Hz power. The MTC preparation pulse was followed by acquisition through fast spin-echo imaging. The imaging parameters were number of excitations (NEX) = 1, echo time (TE) = 14 msec, recovery time (TR) = 2 sec, echo train length of eight echos, and a matrix size of 256 x 160. To reduce motion artifacts, the volunteers were asked to fixate on a blinking LED. Normal and MTC-enhanced images were acquired from normal volunteers and volunteers with nuclear or cortical cataracts. RESULTS The eye was adequately imaged, with few motion artifacts appearing. The lens was well resolved, despite the short T(2). The cornea and ciliary body were also clearly visible. In the lens, resolution of the epithelium and cortex were enhanced with MTC. In addition, contrast-to-noise ratios were measured for each image. Examination of the contrast-to-noise ratio confirmed that MTC increased the contrast between the nucleus and cortex. Unenhanced MRIs showed significant differences between the cortex of normal volunteers and volunteers with cataracts. MTC-enhanced images improved the sensitivity to changes in the nucleus. CONCLUSIONS In this preliminary study, we were able to use MTC-enhanced MRI to obtain high-contrast images of the human lens. Regular and enhanced MRIs detected statistically significant differences between normal and cataractous lenses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Synthesis and evaluation of chitosan manganese-ferrite nanoparticles as MRI contrast agent

Magnetic nanoparticles are the good choice for using in MRI as the contrast agent. Iron oxide particles such as magnetite (Fe3O4) or its oxidized form maghemite (γ-Fe2O3) are the most commonly employed in biomedical applications. In this study, we synthesized and optimized the preparation of chitosan manganese-ferrite nanoparticles (CMn-Fe nps) and evaluated its ability for the mice macrophage ...

متن کامل

Synthesis and evaluation of chitosan manganese-ferrite nanoparticles as MRI contrast agent

Magnetic nanoparticles are the good choice for using in MRI as the contrast agent. Iron oxide particles such as magnetite (Fe3O4) or its oxidized form maghemite (γ-Fe2O3) are the most commonly employed in biomedical applications. In this study, we synthesized and optimized the preparation of chitosan manganese-ferrite nanoparticles (CMn-Fe nps) and evaluated its ability for the mice macrophage ...

متن کامل

Analytical determination of the chemical exchange saturation transfer (CEST) contrast in molecular magnetic resonance imaging

Magnetic resonance based on molecular imaging allows tracing contrast agents thereby facilitating early diagnosis of diseases in a non-invasive fashion that enhances the soft tissue with high spatial resolution. Recently, the exchange of protons between the contrast agent and water, known as the chemical exchange saturation transfer (CEST) effect, has been measured by applying a suitable pulse ...

متن کامل

Magnetization transfer contrast enhancement due to intermolecular multiple quantum coherences - quantitative analysis and tissue dependency

Introduction Recently published studies [1,2], showed an increased sensitivity of intermolecular multiple quantum coherences (iMQC) to magnetization transfer (MT) effects compared to single quantum coherences (SQC). The image contrast in magnetization transfer contrast (MTC) MRI is proportional to (Mz/M0) , where Mz is the actual longitudinal magnetization, M0 is the equilibrium magnetization a...

متن کامل

A Novel Classification Method using Effective Neural Network and Quantitative Magnetization Transfer Imaging of Brain White Matter in Relapsing Remitting Multiple Sclerosis

Background: Quantitative Magnetization Transfer Imaging (QMTI) is often used to quantify the myelin content in multiple sclerosis (MS) lesions and normal appearing brain tissues. Also, automated classifiers such as artificial neural networks (ANNs) can significantly improve the identification and classification processes of MS clinical datasets.Objective: We classified patients with relapsing-r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 41 12  شماره 

صفحات  -

تاریخ انتشار 2000