Clinical evaluation of a trabecular microbypass stent with phacoemulsification in patients with open-angle glaucoma and cataract

نویسندگان

  • Tanner J Ferguson
  • John P Berdahl
  • Justin A Schweitzer
  • Ramu G Sudhagoni
چکیده

PURPOSE To evaluate the safety and efficacy of the iStent trabecular microbypass stent in combination with cataract surgery in patients with open-angle glaucoma (OAG). METHODS Retrospective, consecutive case series from October 2012 to December 2015 with no exclusion criteria. The series comprised of 350 eyes with OAG and cataract. Data were collected both preoperatively and postoperatively at day 1 week 1, months 1, 3, 6, 12, 18, and 24. Data included intraocular pressure (IOP), number of glaucoma medications, visual acuity, the incidence of postoperative IOP pressure spikes of greater than ≥15 mmHg at any time point, and need for additional surgery. RESULTS The mean preoperative IOP was 19.13±6.34 mmHg. At 2 years postoperation, mean IOP was 15.17±3.53 mmHg (P<0.0001). The mean number of glaucoma medications was 1.19±1.00 preoperatively and 0.61±0.96 (P<0.0001) at 2 years postoperation. At 1 day postoperatively, 31 eyes (12.4%) experienced an IOP increase of 15 mmHg above their baseline IOP that responded to topical therapy. Two patients required additional tube shunt surgery. CONCLUSION The insertion of the iStent trabecular microbypass stent in combination with cataract surgery effectively lowers IOP in OAG patients. The magnitude of IOP reduction was more significant in patients with higher preoperative pressure. Medication use was also significantly reduced postoperatively. The safety profile appears favorable with a low rate of IOP spikes and only two eyes (<1%) requiring additional surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Outcomes after combined phacoemulsification and trabecular microbypass stent implantation in controlled open-angle glaucoma.

PURPOSE To study the effect of combined phacoemulsification cataract surgery and iStent (trabecular microbypass stent) implantation on intraocular pressure (IOP) and medication use in open-angle glaucoma (OAG) patients with a low mean preoperative IOP. SETTING University of Colorado Health Eye Center, Aurora, Colorado, USA. DESIGN Retrospective case series. METHODS Treatment outcomes anal...

متن کامل

Aqueous Humor Levels of Soluble Fas and Fas-ligand in Patients with Primary Open Angle and Pseudoex-foliation Glaucoma

Background: Glaucoma is one of the most common causes of blindness and is usually associated with elevated intraocular pressure. In patients with primary open angle glau-coma the number of trabecular meshwork cells is decreased. Death of the trabecular meshwork cells may be a result of apoptosis. Objective: To investigate the aqueous humor levels of soluble Fas (sFas) and Fas-Ligand (sFasL) in ...

متن کامل

Aqueous Levels of Anti-Helicobacter Pylori IgG Antibody in Patients with Primary Open Angle and Pseudoexfoliation Glaucoma

Background: Glaucoma is a progressive optic neuropathy and is one of the leading causes of blindness worldwide. Different factors have been contributed in the pathogenesis of glaucoma including H. pylori infection. Objective: To determine the levels of anti-H. pylori IgG antibody in the aqueous humor of patients with pseudoexfoliation and primary open angle glaucoma, in comparison with age and ...

متن کامل

iStent trabecular micro-bypass stent for open-angle glaucoma

Trabecular micro-bypass stents, commonly known as iStents, are micro-invasive glaucoma surgery (MIGS) devices used to treat open-angle glaucoma. Like other MIGS procedures that enhance trabecular outflow, the iStent lowers intraocular pressure (IOP) by creating a direct channel between the anterior chamber and Schlemm's canal. iStents are typically implanted at the time of phacoemulsification f...

متن کامل

iStent® Trabecular Microbypass Stent: An Update

Due to the high rates of complications and failure experienced with current glaucoma procedures, there is a continuous search for a safer and more effective glaucoma surgery. A new class of procedures termed minimally invasive glaucoma surgeries (MIGS) aim to fill this void by offering an alternative method of IOP reduction associated with markedly reduced complication rates and shorter recover...