Initial anatomic investigations of the I-gel airway: a novel supraglottic airway without inflatable cuff.

نویسندگان

  • R M Levitan
  • W C Kinkle
چکیده

The I-gel airway is a novel supraglottic airway that uses an anatomically designed mask made of a gel-like thermoplastic elastomer. We studied the positioning and mechanics of this new device in 65 non-embalmed cadavers with 73 endoscopies (eight had repeat insertion), 16 neck dissections, and six neck radiographs. A full view of the glottis (percentage of glottic opening score 100%) occurred in 44/73 insertions, whereas only 3/73 insertions had epiglottis-only views. Including the eight repeat insertions with a different size, a glottic opening score of > 50% was obtained in all 65 cadavers. The mean percentage of glottic opening score for the 73 insertions was 82% (95% confidence interval 75-89%). In each of the neck dissections and radiographs the bowl of the device covered the laryngeal inlet. We found that the I-gel effectively conformed to the perilaryngeal anatomy despite the lack of an inflatable cuff and it consistently achieved proper positioning for supraglottic ventilation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative evaluation of LMA-Supreme and i-gel supraglottic airway devices with endotracheal intubation during surgical correction of traumatic orbital injuries

Aims. The aim of the study was to compare endotracheal intubation with i-gel and LMA (laryngeal mask airway) supreme supraglottic airway devices in orbital osteosynthesis surgery. Methods. 134 patients undergoing orbital plasty after fracture were enrolled in our study and were randomized into three groups: 43 in the endotracheal intubation group, 42 in the LMA-Supreme group, and 49 patients w...

متن کامل

Successful tracheal intubation using fiberoptic bronchoscope via an I-gel™ supraglottic airway in a pediatric patient with Goldenhar syndrome -A case report-

The I-gel™ is a single-use supraglottic airway device introduced in 2007 which features a non-inflatable cuff and allows passage of a tracheal tube owing to its large diameter and short length of the airway tube. In this case, the authors experienced a difficult airway management on a 4-year-old boy with underlying Goldenhar syndrome who underwent a tonsillectomy. Intubation using a laryngoscop...

متن کامل

A randomised trial to compare i-gel and ProSeal™ laryngeal mask airway for airway management in paediatric patients

BACKGROUND AND AIMS i-gel™ is a newer supraglottic airway device with a unique non-inflatable cuff. We aimed to compare i-gel™ with ProSeal™ laryngeal mask airway (PLMA™) in children scheduled for surgery under general anaesthesia (GA) with controlled ventilation. METHODS This prospective, randomised controlled study was conducted in 100 surgical patients, aged 2-6 years of American Society o...

متن کامل

Comparison between i-gel airway an the proseal laryngeal mask airway in pediatric patients undergoing general anesthesia

Background The I-gel airway is a new supraglottic airway device without an inflatable cuff. In this study we compare the efficacy of the I-gel airway with the Proseal laryngeal mask airway (p-LMA) in children undergoing elective surgery under general anesthesia without use of muscle relaxants. Methods Eighty children, one to twelve years of age posted for elective surgery under general anesthes...

متن کامل

A comparison of supraglottic airway i-gel™ vs. classic laryngeal mask airway in small children

BACKGROUND i-gel™ is a new single-use supraglottic airway device without an inflatable cuff. This study was designed to compare the usefulness of i-gel™ versus a classic laryngeal mask airway (cLMA) in small children. METHODS Sixty-three children (age range : 4-72 months) were randomly assigned to an i-gel™ or cLMA group. We evaluated hemodynamic data, airway sealing ability, the success rate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anaesthesia

دوره 60 10  شماره 

صفحات  -

تاریخ انتشار 2005